IEK
ARMAT AR-A5V TY40 4P F VR Air circuit breaker 125kA release TY 4000A 4P stationary with accessories ~220-240V: shunt trip, undervoltage release, motor operator IEK AR-ACB-4FG-125-4000A-TYCF
SKU: AR-ACB-4FG-125-4000A-TYCF
ETIM: EC000228
5,918,250 ₽
Get back 59,182 ₽ in points
Promo code
FIRST
— cashback ×3 on your first order: 3% in points on the first 50,000 ₽
Analogues by specifications
Please note - in order to improve Customer convenience, we are transitioning from horizontal to vertical busbar connection for frame sizes G and H in the basic configuration. In ACB ARMAT data for frame sizes manufactured from February 2025 (batch 2502), vertical connection is used. Since we have single units of ACB ARMAT frame sizes G and H oriented for horizontal connection in stock - please consult with us before placing an order. ARMAT series Air Circuit Breakers (ACB) are designed to protect power supply networks from short circuits and overloads, as well as for the rapid switching of electrical circuit sections, and are designed for use in electrical installations with a rated operating voltage of up to 690 V and rated currents from 630 to 6300A. These circuit breakers are equipped with electronic trip units with various combinations of functional features, including Modbus communication capability, which, given a breaking capacity of up to 150 kA, allows the use of ACB ARMAT in any type of industrial and civil facilities. Compliant with GOST R 50030.2.
Main circuit connection type
Rear connection
Built-in motor drive
Yes
Height
394.0 мм
Height
394.0 мм
Altitude above sea level
< 2000
Depth
293.0 мм
Overload protection device setting range to
4000 А
Setting range of overload protection device from
1600...4000 А
Instantaneous short-circuit release setting range to
80000 А
Instantaneous short-circuit release setting range from
4000...80000 А
Auxiliary device factory-installed
Shunt release (for power circuit breakers)
Design
Stationary
Number of auxiliary NO contacts
0
Number of auxiliary changeover contacts
6
Number of auxiliary break contacts
0
Number of poles
4
Design
Other
Mechanical endurance without maintenance
12500
Motor drive optional
No
Electronic release available
Yes
Rated impulse withstand voltage
12
Rated short-time withstand current Icw for 1 s
125
Rated service short-circuit breaking capacity Ics
125
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
125 кА
Rated insulation voltage Ui
1250 В
Rated voltage up to
690 В
Rated voltage from
690...690 В
Rated current
4000 А
Rated continuous current Iu
4000 А
Suitable for DIN-rail mounting
No
Power loss
680 Вт
Operating mode
Continuous
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP30
Product/component type
Air circuit breaker
Main electrical circuit connection type
Bolted connection
Control element type
Other
Mains supply frequency
50 Гц
Width
785.0 мм
Electrical endurance without maintenance at AC 690V
2000
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
2083 ₽
КЭАЗ Circuit breaker 1p 10A 1.3Icn 1.8kA A63 M U3 400V AC KEAZ 104011
SKU: 104011
2083 ₽
КЭАЗ Circuit breaker 1P 16A 5I 1.8kA A63 M U3 400V AC KEAZ 104079
SKU: 104079
3891 ₽
Legrand (группа IEK) Circuit breaker 4p 16A 16kA DPX3 160 thermomagnetic trip Leg 420010 Legrand
SKU: 420010
3181 ₽
КЭАЗ Circuit breaker 2p 1.6A 3.5In 0.3kA AP50B 2MT U3 400V AC/220V DC additional contacts 1changeover KEAZ 107025
SKU: 107025