IEK
ARMAT Residual current circuit breaker B10N 1P+N B20 100mA type A (36mm) IEK AR-B10N-1N-B020A100
SKU: AR-B10N-1N-B020A100
ETIM: EC000905
3,127 ₽
Get back 31 ₽ in points
Analogues by specifications
ARMAT B10N series residual current circuit breakers (RCCB) with 1P+N pole topology are a reliable solution for industrial, power engineering, and domestic applications. A rated breaking capacity of 10 kA guarantees reliable operation of the device even at high short-circuit currents. The B10N 1P+N pole topology means that the protection functions against overload and short-circuit currents, as well as the arc-extinguishing ferromagnetic grid, are implemented in the phase pole. An independent free-trip mechanism with instantaneous switching ensures safe connection, and the terminal protective shutter prevents incorrect connection and errors during conductor installation. PIN and FORK busbar connection is implemented at the top and bottom of the device. B10N 1P+N allows for the connection of any additional ARMAT AUX series modular devices (additional contacts and trip units), as well as an RHN type rotary handle, an HLC type handle locking, and an OTL type sealing plug. The product range includes devices with rated currents from 6 A to 63 A, with B and C overcurrent trip characteristics, type A differential current protection characteristic, with rated differential trip currents of 30, 100, 300 mA.
Mounting installation depth
76 мм
Current limiting class
3
Number of protected poles
1
Number of poles
1P+N
Maximum supply cable cross-section
25 кв.мм
Mechanical durability
20000
Tightening torque of contact terminal screws
5
Availability of residual current release
Yes
Thermal release available
Yes
Electromagnetic release present
Yes
Electronic release available
No
Rated impulse withstand voltage
4
Rated non-tripping residual current
0.5IΔn
Rated differential making and breaking capacity
10000
Rated breaking capacity in accordance with EN 60898
10 кА
Rated breaking capacity per IEC 60947-2
10 кА
Rated voltage
230 В
Rated current
20 А
Rated leakage current
0.1 мА
Total number of poles
2
Operating mode
Continuous
Current type
Alternating current (AC)
With switched neutral conductor
Yes
Tripping system
Thermal, electromagnetic
Mounting method
On DIN rail
Pollution degree (number)
2
IP protection rating
IP20
Operating temperature
-25...55
Residual current type
Please provide the text you would like me to translate.
Connection type
Screw connection
Tripping characteristic
Please provide the text you would like me to translate.
Frequency (Hz)
50/60 Hz
Width in modular units
2
Electrical wear resistance
10000
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
4779 ₽
CHINT Residual current circuit breaker 2p B 25A 300mA type A 10kA RCCB NB1L B25 electromechanical (R) CHINT 205037
SKU: 205037
Price on request
CHINT Residual current circuit breaker (RCCB) NXBL-40Y 1P+N B16 300mA type AC 4.5kA electromechanical (R) CHINT 519918
SKU: 519918
1748 ₽
CHINT Residual current circuit breaker 2P (1P+N) D 10A 30mA type AC 6kA AVDT NXBLE-63YH D10 electron. (R) CHINT 515327
SKU: 515327
Price on request
CHINT Residual current circuit breaker (RCCB/RCBO) AVDT NXBL-40Y 1P+N C20 300mA type AC 4.5kA electromechanical (R) CHINT 519903
SKU: 519903