ARMAT B10N series residual current circuit breakers (RCCB) are a reliable solution for industrial, energy, and domestic applications. B10N is functionally independent of mains voltage, ensuring functional operation even in the event of a neutral loss. A rated maximum breaking capacity of 10 kA guarantees reliable device operation even at high short-circuit currents. The B10N 2P pole topology means that overcurrent and short-circuit protection functions, as well as the arc-extinguishing ferromagnetic grid, are implemented in each pole. An independent free-trip mechanism with instantaneous switching ensures safe connection, and the protective shutter prevents incorrect connection and installation errors. PIN and FORK busbar connections are implemented at the top and bottom of the device. B10N allows the connection of any additional ARMAT AUX series modular devices. The product range includes devices with rated currents from 8 to 32 A, trip characteristics B and C, and protection types AC and A with rated residual currents of 30, 100, 300 mA.
Mounting installation depth
75.6 мм
Current limiting class
3
Number of protected poles
2
Number of poles
2
Maximum supply cable cross-section
16 кв.мм
Mechanical durability
20000
Tightening torque of contact terminal screws
5
Availability of residual current release
Yes
Thermal release available
Yes
Electromagnetic release present
Yes
Electronic release available
No
Rated impulse withstand voltage
4
Rated non-tripping residual current
0.5IΔn
Rated differential making and breaking capacity
10000
Rated breaking capacity in accordance with EN 60898
10 кА
Rated breaking capacity per IEC 60947-2
10 кА
Rated voltage
230 В
Rated current
25 А
Rated leakage current
0.3 мА
Total number of poles
2
Operating mode
Continuous
Current type
Alternating current (AC)
With switched neutral conductor
Yes
Tripping system
Thermal, electromagnetic
Mounting method
On DIN rail
Pollution degree (number)
2
IP protection rating
IP20
Operating temperature
-25...55
Residual current type
A
Connection type
Screw connection
Tripping characteristic
B
Frequency (Hz)
50 Hz
Width in modular units
2
Electrical wear resistance
10000
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
734 ₽
EKF Residual current circuit breaker with overcurrent protection AD-12 1P+N 40A curve C 30mA type AC electronic 4.5kA BASIC DA12-40-30-bas EKF
SKU: DA12-40-30-bas
806 ₽
Контактор (группа IEK) Differential circuit breaker AD-063 2P 40A Idn-100mA type A CONTACTOR 7000615
SKU: 7000615
973 ₽
Эра Residual current circuit breaker 2p (1P+N) C 25A 10mA type A 4.5kA AD-32 electronic PRO D32E2C25A10 Era B0057396
SKU: Б0057396
773 ₽
КЭАЗ Residual current circuit breaker 2p C 16A 30mA type AC 4.5kA АД12-22C16-AC-УХЛ4 with overcurrent protection КЭАЗ 318369
SKU: 318369