IEK
ARMAT Molded case circuit breaker 4P frame size D 150kA 160A adjustable thermomagnetic trip IEK AR-MCCB-4D-150-0160A-ATUC
SKU: AR-MCCB-4D-150-0160A-ATUC
ETIM: EC000228
113,512 ₽
Get back 1,135 ₽ in points
Analogues by specifications
ARMAT molded case circuit breakers are used in various types of low-voltage switchgear – from distribution boards to MCCB 1600 A. They are part of integrated solutions based on ARMAT IEK products for creating power distribution systems for buildings and structures, including industrial and high-tech facilities.
Due to high breaking capacity (up to 150 kA), the ARMAT molded case circuit breaker line is ideal for use in energy-intensive industrial facilities. In combination with ARMAT air circuit breakers, they are used in MCCB up to 6300 A.
The entire ARMAT power circuit breaker line (air and molded case) is manufactured on modern, fully automated equipment with constant quality control.
IEK electrical products are thoroughly tested both in independent laboratories and in the IEK GROUP's own laboratory in Moscow.
We are confident in the high quality and reliability of the ARMAT line power breakers – that is why their service warranty period is 5 years!
Weight
2.160 кг
Main circuit connection type
Other
Built-in motor drive
No
Height
263.0 мм
Height
263.0 мм
Altitude above sea level
< 2000
Depth
117.4 мм
Overload protection device setting range to
1600 А
Setting range of overload protection device from
800...1600 А
Instantaneous short-circuit release setting range from
Please provide the text you would like me to translate. А
Design
Stationary
Number of auxiliary NO contacts
0
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
0
Number of poles
4
Design
Other
Mech. endurance
20000
Mechanical endurance without maintenance
20000
DIN rail mounting (O-type) optional
No
Motor drive optional
Yes
Electronic release available
No
Rated impulse withstand voltage
8
Rated service short-circuit breaking capacity Ics
150
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
150 кА
Rated voltage
400/690 В
Rated insulation voltage Ui
800 В
Rated voltage up to
690 В
Rated voltage from
400...690 В
Rated current
160 А
Rated continuous current Iu
160 А
Relative air humidity
90%
Suitable for DIN-rail mounting
No
Power loss
35.1 Вт
Operating mode
Continuous
With minimum voltage protection
Yes
Tripping system
Thermal-magnetic
IP protection rating
IP20
Terminal ingress protection IP
IP00
Operating temperature from
-40...60 град.C
Product/component type
Moulded case circuit breaker
Main electrical circuit connection type
Bolted connection
Control element type
Toggle switch
Mains supply frequency
50/60 Гц
Width
140.0 мм
Electrical endurance
10000
Electrical endurance without maintenance at AC 440V
10000
Electrical endurance without maintenance at AC 690V
10000
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
703525 ₽
CHINT Air circuit breaker 3p 1250A 55kA NA8-1600N-1250S/3P AC 230V type S stat. (R) CHINT 530565
SKU: 530565
26595 ₽
CHINT Circuit breaker 3P 315A 50kA NXM-400S (R) CHINT 131371
SKU: 131371
6848 ₽
CHINT Circuit breaker 3P 63A 25kA NXM-63S (R) CHINT 205889
SKU: 205889
95432 ₽
CHINT Circuit breaker 3p 500A 25kA NM8NDC-630B TM with reg. thermomagnetic release (R) CHINT 269352
SKU: 269352