IEK
ARMAT Contactor KMI-A-10612 LC1D 6A 48V/AC3 1NO/1NC IEK AR-ACC-11-006-048-11
SKU: AR-ACC-11-006-048-11
ETIM: EC000066
1965 ₽
Price list (incl. VAT):
2233 ₽
Available August 20
Order multiple: 50
Availability
| Warehouse | Qty | Unit | Ready for pickup | Delivery to Smolensk | |
|---|---|---|---|---|---|
|
Manufacturer warehouse
Available
|
59 | шт | August 20 | August 20 |
Select a warehouse to order
Electromagnetic contactors are intended for use in control circuits for starting and stopping three-phase asynchronous squirrel-cage induction motors in electrical networks with a rated voltage of up to 660V AC, and can also be used for switching on and off other electrical installations: lighting, heating units, and various inductive loads. Used in fans, pumps, furnaces, crane-girders, and in automatic transfer switch (ATS) systems.
In terms of design and technical characteristics, the KMI-A series contactors comply with the requirements of international and Russian standards GOST R 50030.4.1-2012 (IEC 60947-4-1:2009).
| Response time on closing - control circuit | 22 |
| Response time on opening - control circuit | 19 |
| Height | 77.0 мм |
| Height | 77.0 мм |
| Flexible cable without ferrule - main circuit | 4 |
| Depth | 86.0 мм |
| Release voltage range - control circuit | 0.3...0.6 |
| Operating voltage range - control circuit | 0.8...1.1 |
| Solid cable without ferrule - main circuit | 4 |
| Overcurrent protection - gG fuse - main circuit | 25 |
| Overcurrent protection - gG fuse - additional input contact | 10 |
| Climatic version | UKhL4 |
| Number of auxiliary NO contacts | 1 |
| Number of auxiliary break contacts | 1 |
| Number of main NO contacts | 3 |
| Number of main NC contacts | 0 |
| Switching wear life - total resource (Hz) | Please provide the text you would like me to translate. You have only provided "2.1", which contains no meaningful text to translate according to the rules. |
| Tightening torque - main circuit | 1.7 |
| Max. short-time load - main circuit | 210 |
| Max short-term load - additional input contact | 140 |
| Mechanical endurance - main circuit | 15 |
| Mechanical durability - control circuit | 15.0 |
| Minimum making capacity Imin - auxiliary circuit contact | 0 |
| Min. making capacity Umin - aux. contact circuit | 17 |
| Modular design | No |
| Coil power consumption at pick-up Uc - control circuit | 70.0 |
| Coil power consumption at holding Uc - control circuit | 7.0 |
| Power dissipation at Ie AC-1 (Hz) | 1.56 |
| Power dissipation at Ie AC-3 (Hz) | 0.20 |
| Rated impulse voltage Uimp - main circuit | 6 |
| Rated voltage Un AC - additional auxiliary circuit contact | 690 |
| Rated insulation voltage Ui - main circuit | 690 |
| Rated insulation voltage Ui-aux. contact circuit | 690 |
| Rated AC operating voltage Ue - main circuit | 690 |
| Rated power at AC-3, 400 V | 4 кВт |
| Rated control supply voltage Us AC at 50 Hz up to | 48 В |
| Rated control supply voltage Us AC at 50 Hz from | 48 В |
| Rated control supply voltage Us DC from | Please provide the text you would like me to translate. В |
| Rated operational current Ie at AC-1, 400 V | 25 А |
| Rated operating current Ie at AC-3, 400 V | 6 А |
| Switch-on current type | Alternating current (AC) |
| Light indication | No |
| IP protection rating | IP20 |
| Operating temperature from | -25...50 град.C |
| Main electrical circuit connection type | Screw connection |
| Electronic relay design | RTI-1310 |
| Thermal withstand current Ith, aux. contact circuit | 10 |
| Conventional thermal current Ith at AC-1 - main circuit | 18 |
| Conditional short-circuit current Inc - main circuit | 1000 |
| Switching frequency for switching endurance per hour - main circuit | 3600 |
| Switching frequency for mechanical durability per hour - main circuit | 3600 |
| Width | 45.0 мм |
0
★★★★★