Electromagnetic contactors are intended for use in control circuits for starting and stopping three-phase asynchronous squirrel-cage induction motors in electrical networks with a rated voltage of up to 660V AC, and can also be used for switching on and off other electrical installations: lighting, heating units, and various inductive loads. Used in fans, pumps, furnaces, crane-girders, and in automatic transfer switch (ATS) systems.
In terms of design and technical characteristics, the KMI-A series contactors comply with the requirements of international and Russian standards GOST R 50030.4.1-2012 (IEC 60947-4-1:2009).
Response time on closing - control circuit
35
Response time on opening - control circuit
20
Height
127.0 мм
Flexible cable without ferrule - main circuit
50
Depth
125.0 мм
Release voltage range - control circuit
0.3...0.6
Operating voltage range - control circuit
0.8...1.1
Solid cable without ferrule - main circuit
50
Overcurrent protection - gG fuse - main circuit
200
Overcurrent protection - gG fuse - additional input contact
10
Climatic version
UKhL4
Number of auxiliary NO contacts
1
Number of auxiliary break contacts
1
Number of main NO contacts
3
Number of main NC contacts
0
Switching wear life - total resource (Hz)
1.7
Tightening torque - main circuit
9.0
Max. short-time load - main circuit
990
Max short-term load - additional input contact
140
Mechanical endurance - main circuit
15
Mechanical durability - control circuit
15.0
Minimum making capacity Imin - auxiliary circuit contact
0
Min. making capacity Umin - aux. contact circuit
17
Modular design
No
Coil power consumption at pick-up Uc - control circuit
245.0
Coil power consumption at holding Uc - control circuit
26.0
Power dissipation at Ie AC-1 (Hz)
12.50
Power dissipation at Ie AC-3 (Hz)
5.10
Rated impulse voltage Uimp - main circuit
8
Rated voltage Un AC - additional auxiliary circuit contact
690
Rated insulation voltage Ui - main circuit
1000
Rated insulation voltage Ui-aux. contact circuit
690
Rated AC operating voltage Ue - main circuit
690
Rated power at AC-3, 400 V
37 кВт
Rated control supply voltage Us AC at 50 Hz up to
400 В
Rated control supply voltage Us AC at 50 Hz from
400 В
Rated control supply voltage Us DC from
Please provide the text you would like me to translate. В
Rated operational current Ie at AC-1, 400 V
125 А
Rated operating current Ie at AC-3, 400 V
80 А
Switch-on current type
Alternating current (AC)
Light indication
No
IP protection rating
IP20
Operating temperature from
-25...50 град.C
Main electrical circuit connection type
Screw connection
Electronic relay design
RTI-3363
Thermal withstand current Ith, aux. contact circuit
10
Conventional thermal current Ith at AC-1 - main circuit
125
Conditional short-circuit current Inc - main circuit
5000
Switching frequency for switching endurance per hour - main circuit
3600
Switching frequency for mechanical durability per hour - main circuit
3600
Width
86.0 мм
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
61336 ₽
CHINT NC2-150NS reversing contactor 150A 110V AC-3 50Hz (R) CHINT 235738
SKU: 235738
2527 ₽
CHINT Contactor NXC-06M/22/Z 6A cat. 110V DC 2NO+2NC (R) CHINT 836683
SKU: 836683
1403 ₽
CHINT Contactor NXC-09 3p 9A cat. 36V AC (50/60Hz) 1NO+1NC (R) CHINT 925361
SKU: 925361
5655 ₽
Legrand Contactor CTX³ 100 3P 100A (AC-3) 2no2nc ~110V 416234 Legrand
SKU: 416234