ARMAT R10N series residual current devices provide protection against electric shock to humans, as well as fire protection in case of a ground fault. The model range includes devices with differential current protective characteristics of types AC, A, AC-S, A-S; rated currents from 25 to 100 A; rated residual currents from 10 to 300mA. The rated breaking capacity of ARMAT R10N series RCD is 10 kA.
Weight
0.2 кг
Additional equipment possible
No
Mounting installation depth
76.0 мм
Number of poles
2
Maximum supply cable cross-section
35 кв.мм
Mech. endurance
10000
Tightening torque from
5 Н·м
Rated impulse withstand voltage
4
Rated non-tripping residual current
150.0
Rated leakage current
0.30
Rated ultimate breaking capacity (Icw)
10 кА
Rated voltage
230 В
Rated insulation voltage Ui
500 В
Rated voltage from
230 В
Rated current
100 А
Rated current
100 А
Rated leakage current
It appears your message contains only ".3". Please provide the text you would like me to translate from Russian to English, and I will follow your instructions strictly. мА
Ambient operating temperature to
45 град.C
Ambient operating temperature from
-25...45 град.C
Leakage current adjustment
No
Adjustable delay time
No
Operating mode
Continuous-S1
With short-time delayed tripping
No
With interlock device
No
Selective protection
No
Flexible stranded conductor cross-section up to
35 кв.мм
Stranded flexible conductor cross-section from
1.5...35 кв.мм
Solid conductor cross-section to
35 кв.мм
Solid conductor cross-section from
1.5...35 кв.мм
Mounting method
On DIN rail
IP protection rating
IP20
Installation size (in accordance with DIN 43880)
2
Residual current type
Alternating current (AC)
Conditional rated residual short-circuit current
10
Resistance to current surges
Please provide the text you would like me to translate. кА
Frequency
50 Hz Гц
Frequency (Hz)
50 Hz
Width in modular units
2
Electrical endurance
6000
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
4156 ₽
EKF Residual current device VD-100N 2P 25A 300mA AC electromechanical 6kA PROXIMA EKF E1026M25300
SKU: E1026M25300
4661 ₽
DEKraft Residual Current Device (RCD) 4p 32A 300mA type A 6kA УЗО-03 DEKraft 14305DEK
SKU: 14305DEK
3832 ₽
DKC Residual Current Device YON max (YON max) type MDL100, 4 poles, 100mA, 16A, type A MDL100-4P3-16-A DKC
SKU: MDL100-4P3-16-A
3476 ₽
EKF Residual current device VD-100 4P (S) 63A 300mA type AC electromechanical 4.5kA selective PROXIMA EKF elcb-4-63-300S-em-pro
SKU: elcb-4-63-300S-em-pro