IEK
ARMAT Residual Current Circuit Breaker R10N 2P 100A 30mA type A IEK AR-R10N-2-100A030
SKU: AR-R10N-2-100A030
ETIM: EC000003
11,026 ₽
Get back 110 ₽ in points
Analogues by specifications
ARMAT R10N series residual current devices provide protection against electric shock to humans, as well as fire protection in case of a ground fault. The model range includes devices with differential current protective characteristics of types AC, A, AC-S, A-S; rated currents from 25 to 100 A; rated residual currents from 10 to 300mA. The rated breaking capacity of ARMAT R10N series RCD is 10 kA.
Weight
0.2 кг
Additional equipment possible
No
Mounting installation depth
76.0 мм
Number of poles
2
Maximum supply cable cross-section
35 кв.мм
Mech. endurance
10000
Tightening torque from
5 Н·м
Rated impulse withstand voltage
4
Rated non-tripping residual current
15.0
Rated leakage current
0.03
Rated ultimate breaking capacity (Icw)
10 кА
Rated voltage
230 В
Rated insulation voltage Ui
500 В
Rated voltage from
230 В
Rated current
100 А
Rated current
100 А
Rated leakage current
.03 мА
Ambient operating temperature to
45 град.C
Ambient operating temperature from
-25...45 град.C
Leakage current adjustment
No
Adjustable delay time
No
Operating mode
Continuous-S1
With short-time delayed tripping
No
With interlock device
No
Selective protection
No
Flexible stranded conductor cross-section up to
35 кв.мм
Stranded flexible conductor cross-section from
1.5...35 кв.мм
Solid conductor cross-section to
35 кв.мм
Solid conductor cross-section from
1.5...35 кв.мм
Mounting method
On DIN rail
IP protection rating
IP20
Installation size (in accordance with DIN 43880)
2
Residual current type
Please provide the text you would like me to translate.
Conditional rated residual short-circuit current
10
Resistance to current surges
Please provide the text you would like me to translate. кА
Frequency
50 Hz Гц
Frequency (Hz)
50 Hz
Width in modular units
2
Electrical endurance
6000
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
5442 ₽
CHINT Residual Current Device (RCD) 4p 63A 300mA type AC AX NL1-63 6kA (R) CHINT 200894
SKU: 200894
3281 ₽
CHINT Residual Current Circuit Breaker (RCCB) 2p 40A 100mA type AC 10kA NL1-63 (DB) (R) CHINT 200378
SKU: 200378
1955 ₽
Эра Residual current device (RCD) 4p 100A 300mA type AC VD1-63 PRO electromechanical VD4EM100AC300 Era Б0061781
SKU: Б0061781
3493 ₽
EKF RCCB DV 4P (S) 40A 100mA Type AC Electromechanical 10kA Selective AVERES EKF rccb-4-40-100-s-av
SKU: rccb-4-40-100-s-av