Legrand (группа IEK)
Modular circuit breaker 2P C 63A 4.5kA RX3 IEK Leg 419703 Legrand (IEK group)
SKU: 419703
ETIM: EC000042
1053 ₽
Price list (incl. VAT):
1053 ₽
Preorder
Order multiple: 6
RX3 series circuit breakers are designed for load control, disconnection of electrical circuits, and protection against overload and short circuits. Suitable for use in residential and small commercial buildings.
| Weight per pole | 0.150 |
| Additional equipment possible | No |
| Busbar connection capability | PIN (pin) |
| Release response time in short-circuit range tm | 0.1 |
| Mounting installation depth | 44 мм |
| For flush mounting | No |
| Overvoltage category | 0 |
| Electric shock protection class | 0 |
| Climatic version | UKhL3 |
| Number of protected poles | 2 |
| Number of normally closed (NC) contacts | 0 |
| Number of changeover contacts | 0 |
| Guaranteed non-tripping factor | 1.13 |
| Guaranteed trip coefficient | 1.45 |
| Maximum supply cable cross-section | 35 кв.мм |
| Mech. endurance | 20000 |
| Explosion protection present | Without explosion protection |
| Availability of residual current release | No |
| Availability of current multiple for I2t function time tm | Yes |
| Thermal release available | Yes |
| Electromagnetic release present | Yes |
| Electronic release available | No |
| Rated impulse withstand voltage | 4 |
| Rated short-circuit breaking capacity Icu IEC 60898 at 230 V | 4.5 кА |
| Rated short-circuit breaking capacity Icu IEC 60898 at 400 V | 4.5 кА |
| Rated short-circuit breaking capacity Icu IEC 60947-2 at 230V | 4.5 кА |
| Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V | 4.5 кА |
| Rated breaking capacity in accordance with EN 60898 | 4.5 кА |
| Rated impulse voltage | 4 кВ |
| Rated voltage | 400 В |
| Rated insulation voltage Ui | 4 В |
| Rated DC voltage from | 110 В |
| Rated current | 63 А |
| Total number of poles | 2 |
| Suitable for load-break switch | Yes |
| Power loss | 5.5 Вт |
| Ambient operating temperature to | 0 град.C |
| Ambient operating temperature from | 30 град.C |
| Operating mode | Continuous-S1 |
| Repairability | No |
| Current type | Alternating current (AC) |
| With switched neutral conductor | No |
| Flexible stranded conductor cross-section up to | 25 кв.мм |
| Stranded flexible conductor cross-section from | 1.5 кв.мм |
| Solid conductor cross-section to | 35 кв.мм |
| Solid conductor cross-section from | 1.5 кв.мм |
| Tripping system | Thermal, electromagnetic |
| Instantaneous release setting method | By multiple (Ki) |
| Trip unit setting method | By type (A/B/C/D...) |
| Mounting method | On DIN rail |
| Pollution degree (number) | 2 |
| IP protection rating | IP20 |
| Application area | Industrial and domestic |
| Tripping characteristic | It seems your message was cut off. Please provide the text you would like me to translate from Russian to English, and I will follow your instructions strictly. |
| Frequency | 50 Гц |
| Frequency at | 60 Гц |
| Frequency from | 50 Гц |
| Width in modular units | 2 |
| Electrical endurance | 10000 |
| Electrodynamic withstand Icm | 4.5 |
0
★★★★★
0 reviews
No reviews yet. Be the first!