Контактор (группа IEK)
Circuit breaker AB2M10H-53-41-800-MP4-10000-UKHL3-RNN-110-VDC-PE220VAC-1p2z 800A electr.mag.release 10000A; max. current release MRT4-MP; min. voltage release 110VDC; electr.mag. drive 220VAC; free contacts 1p2z Contactor 1027683
SKU: 1027683
ETIM: EC000228
526,169 ₽
Get back 5,261 ₽ in points
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Front connection
Built-in ground fault protection
No
Built-in motor drive
Yes
Depth
297.0 мм
Short-time delayed short-circuit release range
288…9600 А
Overload protection device setting range to
880 А
Setting range of overload protection device from
240…800 А
Instantaneous short-circuit release setting range to
12800 А
Instantaneous short-circuit release setting range from
3200 А
Design
Stationary
Climatic version
UKhL3
Number of auxiliary NO contacts
2
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
1
Number of poles
3
Design
Built-in device for built-in appliances
Motor drive optional
Yes
Electronic release available
Yes
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
800 А
Rated continuous current Iu
800 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Main electrical circuit connection type
Bolted connection
Control element type
Other
Mains supply frequency
50/60 Гц
Width
405.0 мм
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
204347 ₽
CHINT 3P 800A circuit breaker 560…800A range 70kA NM8N-800Q TM with adjustable thermomagnetic release (R) as part of DOB24F-M8 CHINT 272941K1
SKU: 272941K1
136136 ₽
CHINT Circuit breaker 3p 400A 36kA NM8N-630C EM with LCD electronic trip unit (R) CHINT 269469
SKU: 269469
404385 ₽
CHINT Air circuit breaker 3p 400A 66kA NA8-1600H-400M/3P AC 230V type M stac. (R) CHINT 536991
SKU: 536991
3435454 ₽
CHINT Air circuit breaker NA8-7500-7500M/4P trip 7500A 135kA type M AC400V (R) CHINT 262881
SKU: 262881
136136 ₽
CHINT Circuit breaker 3p 400A 36kA NM8N-630C EM with LCD electronic trip unit (R) CHINT 269469
SKU: 269469
404385 ₽
CHINT Air circuit breaker 3p 400A 66kA NA8-1600H-400M/3P AC 230V type M stac. (R) CHINT 536991
SKU: 536991
3435454 ₽
CHINT Air circuit breaker NA8-7500-7500M/4P trip 7500A 135kA type M AC400V (R) CHINT 262881
SKU: 262881