Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Rear connection
Built-in ground fault protection
No
Built-in motor drive
No
Height
500.0 мм
Short-time delayed short-circuit release range
288…9600 А
Overload protection device setting range to
880 А
Setting range of overload protection device from
240…800 А
Instantaneous short-circuit release setting range to
12800 А
Instantaneous short-circuit release setting range from
3200 А
For metric pipes
75 мм
Auxiliary device factory-installed
Shunt release (for power circuit breakers)
Design
Withdrawable
Climatic version
UKhL3
Number of auxiliary NO contacts
3
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
4
Number of poles
3
Design
Slot-in device (withdrawable)
Maximum number of cables
1
Clamping bracket material
Steel
Motor drive optional
No
Electronic release available
Yes
Halogen-free
Yes
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
800 А
Rated continuous current Iu
800 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
Operating range at
75 мм
Operating range from
75 мм
With minimum voltage protection
Yes
With metal plate
No
With plastic tray
No
Tripping system
Electronic
Mounting method
C-profile
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Control element type
Extended rotary handle (wide grip)
Mains supply frequency
50/60 Гц
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
2665 ₽
Legrand (группа IEK) Circuit breaker 4p 50A 10kA DRX125 thermomagnetic trip Leg 027015 Legrand
SKU: 027015
3461 ₽
КЭАЗ Circuit breaker 3p 4A 10kA 0.6kA AP50B 3MT U3 400V AC additional contacts 1changeover KEAZ 107342
SKU: 107342
2999 ₽
Legrand (группа IEK) Circuit breaker 3p 125A 25kA DRX 125 HP TM Reg Leg 669009 Legrand
SKU: 669009
3081 ₽
Legrand (группа IEK) 669740, DRX 125 HP TM adj. 3P 16A 50kA Legrand
SKU: 669740