Контактор (группа IEK)
Circuit breaker 3p 2000A AB2M20C-55-43 UHL3 690V Contactor 1040669 Contactor (IEK group)
SKU: 1040669
ETIM: EC000228
781,780 ₽
Get back 7,817 ₽ in points
Promo code
FIRST
— cashback ×3 on your first order: 3% in points on the first 50,000 ₽
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Front connection
Built-in ground fault protection
No
Built-in motor drive
Yes
Depth
320.0 мм
Short-time delayed short-circuit release range
720…24000 А
Overload protection device setting range to
1980 А
Setting range of overload protection device from
600…2000 А
Version
Stationary
Climatic version
UKhL3
Number of auxiliary NO contacts
3
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
3
Number of poles
3
Design
Built-in device for built-in appliances
Motor drive optional
Yes
Electronic release available
Yes
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
2000 А
Rated continuous current Iu
2000 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Main electrical circuit connection type
Bolted connection
Control element type
Other
Mains supply frequency
50/60 Гц
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
5263 ₽
КЭАЗ Circuit breaker 3p 2A 12In 0.4kA AE2046M-400 U3 400V AC KEAZ 104661
SKU: 104661
1458 ₽
Legrand (группа IEK) DRX125 thermomagnetic 15A 1P 36KA 027040 Legrand
SKU: 027040
2083 ₽
КЭАЗ Circuit breaker 1p 3.15A 2Iн 1.8kA A63 M U3 110V DC KEAZ 103977
SKU: 103977
2083 ₽
КЭАЗ Circuit breaker 1p 0.6A 1.3Icn 2.5kA A63 M U3 110V DC KEAZ 103920
SKU: 103920