Контактор (группа IEK)
Circuit breaker AB2M20SV-55-43-2000-MP1-UKHL3-PE220VAC-3r4z 2000A; max current elec. release MRT1-MP; electromagnetic drive 220VAC; free contacts 3r4z Contactor 1045514
SKU: 1045514
ETIM: EC000228
1,280,523 ₽
Get back 12,805 ₽ in points
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Rear connection
Built-in ground fault protection
No
Built-in motor drive
Yes
Short-time delayed short-circuit release range
900…24000 А
Setting range of overload protection device from
600…2000 А
Instantaneous short-circuit release setting range from
1200…24000 А
Design
Withdrawable
Climatic version
UKhL3
Number of auxiliary NO contacts
4
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
3
Number of poles
3
Design
Slot-in device (withdrawable)
Motor drive optional
Yes
Electronic release available
Yes
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
2000 А
Rated continuous current Iu
2000 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Control element type
Other
Mains supply frequency
50/60 Гц
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
204347 ₽
CHINT 3P 800A circuit breaker 560…800A range 70kA NM8N-800Q TM with adjustable thermomagnetic release (R) as part of DOB24F-M8 CHINT 272941K1
SKU: 272941K1
2702735 ₽
CHINT Air circuit breaker NA8-7500H-5000H/3P withdrawable 5000A 150kA type H AC400V (R) CHINT 262913
SKU: 262913
2094587 ₽
CHINT Air circuit breaker NA8-4000H-3200H/4P stac. 3200A 100kA type H DC220V (R) CHINT 262847
SKU: 262847
3801208 ₽
CHINT Air circuit breaker NA8-7500-6300H/4P drawout 6300A 135kA type H AC230V (R) CHINT 262886
SKU: 262886
2702735 ₽
CHINT Air circuit breaker NA8-7500H-5000H/3P withdrawable 5000A 150kA type H AC400V (R) CHINT 262913
SKU: 262913
2094587 ₽
CHINT Air circuit breaker NA8-4000H-3200H/4P stac. 3200A 100kA type H DC220V (R) CHINT 262847
SKU: 262847
3801208 ₽
CHINT Air circuit breaker NA8-7500-6300H/4P drawout 6300A 135kA type H AC230V (R) CHINT 262886
SKU: 262886