Контактор (группа IEK)
Circuit breaker АВ2М4Н-53-41-400-МР4-6300-УХЛ3-НР220ВAC-ПЭ220ВAC-3р3з 400A magnetic release 6300A; max current release МРТ4-МП; independent release 220V AC; electromagnetic drive 220V AC; free contacts 3p3z Contactor 1000549
SKU: 1000549
ETIM: EC000228
536,511 ₽
Get back 5,365 ₽ in points
Analogues by specifications
Stock by warehouse
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Front connection
Built-in ground fault protection
No
Built-in motor drive
Yes
Depth
297.0 мм
Short-time delayed short-circuit release range
144…5280 А
Overload protection device setting range to
440 А
Setting range of overload protection device from
120…440 А
Instantaneous short-circuit release setting range to
6400 А
Instantaneous short-circuit release setting range from
1600 А
Design
Stationary
Climatic version
UKhL3
Number of auxiliary NO contacts
3
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
3
Number of poles
3
Design
Built-in device for built-in appliances
Motor drive optional
Yes
Electronic release available
Yes
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
400 А
Rated continuous current Iu
400 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Main electrical circuit connection type
Bolted connection
Control element type
Other
Mains supply frequency
50/60 Гц
Width
405.0 мм
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
38888 ₽
CHINT Circuit breaker 2p 125A 36kA NM8NDC-250C TM with thermomagnetic trip (R) CHINT 274850
SKU: 274850
49897 ₽
CHINT Circuit breaker 3p 100A 50kA NM8N-250S EN with electronic trip unit (R) CHINT 271333
SKU: 271333
2045926 ₽
CHINT Air circuit breaker NA8-2500HU-1600M/4P drawout 1600A 65kA type M AC 230V (R) CHINT 406161
SKU: 406161
168348 ₽
CHINT Molded Case Circuit Breaker 4p 400A 100kA NM8N-630H EN with elec. trip (R) CHINT 269440
SKU: 269440