Automatic circuit breaker AV2M4NV-53-41-400-MP4-6300-UKHL3-NR220VAC-PE220VAC-3p3z 400A elect. mag. release 6300A; max. current release MRT4-MP; independent release 220VAC; elect. mag. drive 220VAC; free contacts 3p3z Contactor 1011794
SKU: 1011794
ETIM: EC000228
1,468,232 ₽
Get back 14,682 ₽ in points
Order multiple: 2 шт
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Built-in ground fault protection
No
Overload protection device setting range to
440 А
Setting range of overload protection device from
120 А
Instantaneous short-circuit release setting range to
6400 А
Instantaneous short-circuit release setting range from
1600 А
Number of auxiliary NO contacts
0
Number of auxiliary break contacts
0
Number of poles
3
Design
Built-in withdrawable device
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated continuous current Iu
400 А
Suitable for DIN-rail mounting
No
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
1683096 ₽
CHINT Air circuit breaker 4p 2000A 85kA NA8-2500H-2000S/4P AC 400V type S stac. (R) CHINT 532515
SKU: 532515
809053 ₽
CHINT Air circuit breaker 3p 1250A 66kA NA8-1600H-1250S/3P AC 400V type S stationary (R) CHINT 530574
SKU: 530574
50446 ₽
CHINT Circuit breaker 3p 20A 70kA NM8NDC-125Q TM with thermomagnetic release (R) CHINT 271762
SKU: 271762
243619 ₽
CHINT Circuit breaker NM8NDC-1600B TM 4p 800A 25kA with reg. thermomagnetic release (R) CHINT 263158
SKU: 263158