Контактор (группа IEK)
Circuit breaker AB2M4SV-55-41-UHL3 250A 690V with MRT1-MP block Contactor 1045166 Contactor (IEK group)
SKU: 1045166
ETIM: EC000228
613,029 ₽
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Rear connection
Built-in ground fault protection
No
Built-in motor drive
No
Height
500.0 мм
Short-time delayed short-circuit release range
112.5…3300 А
Setting range of overload protection device from
75…275 А
Instantaneous short-circuit release setting range from
150…3300 А
Version
Withdrawable
Climatic version
UKhL3
Number of auxiliary NO contacts
4
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
4
Number of poles
3
Design
Slot-in device (withdrawable)
Motor drive optional
No
Electronic release available
Yes
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
250 А
Rated continuous current Iu
250 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Control element type
Extended rotary handle (wide grip)
Mains supply frequency
50/60 Гц
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
23811 ₽
LS Electric Circuit breaker 3p 3t 125A 50kA TD160N FTU LS Electric 0102006400
SKU: 0102006400
227852 ₽
Контактор (группа IEK) Circuit breaker A3793СУХЛ3 Stac Ruch 250A 440V manual front connection busbar cable with copper lug IP20 Contactor 1010880
SKU: 1010880
16105 ₽
Legrand 423256, DPX3 250HP EL S1 4P 100A 100kA Legrand
SKU: 423256
10865 ₽
КЭАЗ Circuit breaker 2p 200A 1250Im 40kA BA57-35-840010 UHL3 220V DC KEAZ 222640
SKU: 222640