EKF
Residual current circuit breaker AD-32 3P+N (S) 20A characteristic C 100mA type AC electronic selective 6kA PROXIMA EKF DA32-6-20-100S-4P-pro
SKU: DA32-6-20-100S-4P-pro
ETIM: EC000905
3,512 ₽
Get back 35 ₽ in points
Analogues by specifications
AD-32 residual current circuit breaker (RCBO) is used in AC electrical circuits with a rated voltage of 230V/400V and a frequency of 50 Hz in residential and public buildings. It is designed to protect people from electric shock upon accidental contact with exposed conductive parts of electrical installations. It protects electrical installations (EI) during conductor insulation damage and EI faults, prevents fires and ignitions resulting from leakage currents and subsequent short circuits, ground faults, and earth faults. It provides automatic disconnection of a section of the electrical network during overloads and short-circuit currents.
Mounting installation depth
73 мм
For flush mounting
Yes
False tripping protection
No
Overvoltage category
3
Current limiting class
3
Number of protected poles
3
Rated breaking capacity in accordance with EN 60898
6 кА
Rated breaking capacity per IEC 60947-2
6 кА
Rated short-circuit breaking capacity Icn per EN 61009-1
6 кА
Rated impulse voltage
6 кВ
Rated voltage
400 В
Rated insulation voltage Ui
500 В
Rated current
20 А
Rated leakage current
0.1 мА
Total number of poles
4
Ambient operating temperature to
55 град.C
Ambient operating temperature from
-25...55 град.C
Current type
AC (alternating)
With switched neutral conductor
Yes
With interlock device
No
Flexible stranded conductor cross-section up to
16 кв.мм
Stranded flexible conductor cross-section from
0...16 кв.мм
Solid conductor cross-section to
25 кв.мм
Solid conductor cross-section from
0...25 кв.мм
Pollution degree (number)
3
IP protection rating
IP20
Residual current type
AC/S
Resistance to current surges
6 кА
Tripping characteristic
Selective
Tripping characteristic
It seems your message was cut off. Please provide the text you would like me to translate from Russian to English, and I will follow your instructions strictly.
Frequency (Hz)
50 Hz
Width in modular units
4.5
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
Price on request
CHINT Residual current circuit breaker (RCCB/RCBO) AVDT NXBL-40Y 1P+N C40 30mA type A 4.5kA electromechanical (R) CHINT 519866
SKU: 519866
50057 ₽
CHINT Residual current circuit breaker 4p (3P+N) C 40A 10mA type AC 6kA AVDT NB2LE-80ZT electronic (R) CHINT 448228
SKU: 448228
3404 ₽
CHINT Residual current circuit breaker 2P (1P+N) B 32A 100mA type A 6kA AVDT NB1L B32 electromechanical (R) CHINT 203258
SKU: 203258
3906 ₽
CHINT Residual current circuit breaker 4p (3P+N) C 6A 30mA type AC 6kA AVDT NXBLE-63YH C6 electron. (R) CHINT 539784
SKU: 539784