EKF
Residual current circuit breaker DVA-6 1P+N 16A characteristic C 10mA type A electromechanical 6kA AVERES EKF rcbo6-1pn-16C-10-a-av
SKU: rcbo6-1pn-16C-10-a-av
ETIM: EC000905
4,699 ₽
Get back 46 ₽ in points
Promo code
FIRST
— cashback ×3 on your first order: 3% in points on the first 50,000 ₽
Analogues by specifications
Stock by warehouse
DVA-6 and DVA-10 series AVERES residual current circuit breakers (RCCB) are used in AC electrical circuits with a rated voltage of 230 V / 400 V and a frequency of 50 / 60 Hz. They are designed to protect people from electric shock upon accidental contact with live parts of an electrical installation and to protect electrical equipment in case of conductor insulation damage and faults; they prevent fires resulting from leakage currents and subsequent short circuits, ground faults, and earth faults; they ensure automatic disconnection of a section of the electrical network during overloads and short circuits. Protective shutters on the breaker terminals cover the space behind the terminal and make incorrect conductor connection impossible. The molded front panel of the breaker features a color indicator of the physical state of the contact group and a window for convenient circuit marking. DVA-6 and DVA-10 series AVERES residual current circuit breakers comply with GOST IEC 61009-1.
Mounting installation depth
79 мм
For flush mounting
Yes
False tripping protection
No
Overvoltage category
3
Current limiting class
3
Number of protected poles
1
Rated breaking capacity per IEC 60947-2
6 кА
Rated short-circuit breaking capacity Icn per EN 61009-1
6 кА
Rated impulse voltage
6 кВ
Rated voltage
230 В
Rated insulation voltage Ui
500 В
Rated current
16 А
Rated leakage current
0.01 мА
Total number of poles
2
Ambient operating temperature to
50 град.C
Ambient operating temperature from
-40...50 град.C
Current type
AC (alternating)
With switched neutral conductor
Yes
With interlock device
No
Flexible stranded conductor cross-section up to
16 кв.мм
Stranded flexible conductor cross-section from
0...16 кв.мм
Solid conductor cross-section to
25 кв.мм
Solid conductor cross-section from
0...25 кв.мм
Pollution degree (number)
3
IP protection rating
IP20
Residual current type
A
Resistance to current surges
6 кА
Tripping characteristic
Without delay
Tripping characteristic
C
Frequency (Hz)
50/60 Hz
Width in modular units
2
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
961 ₽
EKF RCBO AD-2 2P 32A characteristic C 100mA type AC electronic 6kA PROXIMA EKF DA2-6-32-100-pro
SKU: DA2-6-32-100-pro
1012 ₽
Generica (Группа IEK) Residual Current Circuit Breaker AD12 2P 50A 100mA GENERICA MAD15-2-050-C-100
SKU: MAD15-2-050-C-100
948 ₽
TDM ELECTRIC AVDT 32 2P(1P+N) C63A 30mA 4.5kA type AC TDM SQ0202-0513
SKU: SQ0202-0513
1081 ₽
DEKraft Residual current circuit breaker 2p (1P+N) D 40A 30mA type AC DIF-101 with built-in overcurrent protection DEKraft 15170DEK
SKU: 15170DEK