62 ₽
Get back 1% in points
Analogues by specifications
The cable is used for group installation in fire alarm systems. It is used in the organization of access control and communication systems, as well as for other control systems.
KPSVEV ng(A)-LS cable is designed for indoor and outdoor use, provided it is protected from direct exposure to solar radiation and atmospheric precipitation. Manufactured according to TU 27.32.13-009-39644825-2020.
4 single-wire current-carrying conductors with a cross-section of 0.50 mm2 are made of copper and have undergone 100% annealing, making the cable softer, which simplifies the installation process and increases service life. The conductors are insulated with low-fire-hazard polyvinyl chloride plastisol and are twisted together, which increases signal range and reduces interference.
A longitudinal screen made of laminated aluminum foil with a contact conductor is applied over the conductors.
The conductors and the screen are insulated with a polyvinyl chloride plastisol sheath with low fire hazard and low smoke and gas emission.
Installation temperature: –10…+50 °C.
Armoured
No
Conductor diameter
It appears your message contains only ".8". Please provide the text you would like me to translate from Russian to English, and I will follow your instructions strictly. мм
For laying in the ground
No
Permissible operating temperature (no movement) to
70 град.C
Permissible operating temperature (without movement) from
-40 град.C
Core insulation
Polyvinyl chloride (PVC)
Insulation per GOST R IEC 60331
Yes
Category
No (without)
Conductor class
1 - single-wire
Number of cores
4
Number of twisted elements
2
Cable/wire grade
KPSVEVng(A)-LS
Core marking
Digits
Oil-resistant
No
Oil-resistant (in accordance with IEC 60811-404)
No
Outer sheath material
Polyvinyl chloride (PVC)
Conductor material
Copper
Outer diameter (approx.)
5.7 мм
Low smoke emission in accordance with EN 61034-2 (ng-LS version)
Yes
Rated conductor cross-section
It appears your message contains only ".5". Please provide the text you would like me to translate from Russian to English, and I will follow your instructions strictly. кв.мм
Fire resistance
In accordance with IEC 60332-3-22
Longitudinal water blocking
No
Radial water blocking
No
Recommended installation temperature during pulling, up to
60 град.C
Recommended installation temperature during pulling from
-10 град.C
With low smoke emission in accordance with IEC 61034-2
Yes
Halogen-free (per EN 60754-1/2)
No
Halogen-free (per IEC 60754-2)
No
Twist type
Bundled
UV resistance
No
Outer sheath colour
Red
Screen over the twist
Foil
Screen over stranding element
Foil
Twisting element
Paired
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
75 ₽
DKC Twisted pair cable Cat. 6 unshielded U/UTP, 4 pairs, ng(A)-LS, outer sheath color white, 305 m reel RN6UUK02WH DKC
SKU: RN6UUK02WH
159 ₽
TOKOV ELECTRIC F/UTP twisted pair cable 4x2x23AWG(0.57mm) cat.6 PVCLS нг(А)-LSLTx indoor 305m (m) PRO TOKOV ELECTRIC TKP-C11-F42-6-RU-LSLTx
SKU: TKP-C11-F42-6-RU-LSLTx
12899 ₽
ITK (группа IEK) ITK Fire-resistant Cable KPSEng(A)-FRLS 1x2x0.50 orange (200m) FR1-01-F-5307
SKU: FR1-01-F-5307
50278 ₽
ITK (группа IEK) ITK Halogen-free cable KPSTETng(A)-HF 2x2x1.0 orange (200m) SAS1-02-F-7207
SKU: SAS1-02-F-7207