control cables with copper cores, with low fire hazard plastic insulation in a low fire hazard polyvinyl chloride sheath, intended for fixed connection to electrical devices, apparatuses, assemblies, and terminals of electrical distribution devices with a rated alternating voltage of up to 660 V at a frequency of up to 100 Hz or a direct voltage of up to 1000 V. Application area of the cables:
KVVGGng(A)-LS - for installation in rooms, channels, tunnels, in aggressive environments, in the absence of mechanical impact on the cable;
Nominal cross-sections of the current-carrying conductors of the cables, mm2: 0.75; 1.0; 1.5; 2.5, 4, 6, 10. Number of current-carrying
conductors: 4, 5, 7, 10, 14, 19, 27, 37.
Cables are manufactured in the climatic design UHL, placement categories 1-5 according to GOST 15150.
Fire hazard class of the cables according to GOST 31565-2012 P1b.8.2.2.2.
Safe operating and installation conditions.
Cable installation must comply with the requirements of the current "Electrical Installation Rules".
Cables can be laid without preheating at a temperature no lower than -15°C.
The bending radius of the cables during laying and installation must be at least 12D_n for KVVGGng(A)-LS cables, where D_n is the outer diameter of the cable.
The cable tension during laying and installation must not create a tensile stress in the current-carrying conductors of more than 4 kg/mm2.
Cables must not propagate fire when laid in bundles according to GOST IEC 60332-3-22-2011.
Cables must be resistant to the effects of ambient temperatures from -50 (-60 for -XL execution cables) to +50°C.
Storage and transportation conditions.
Storage and transportation of cables must be carried out in accordance with GOST 18690. Storage conditions for cables regarding the impact of environmental climatic factors must comply with the OZh4 storage conditions according to GOST 15150-69. Storage of cables on drums in a covered state under a canopy is allowed for no more than 5 years, and in closed rooms for no more than 10 years. Transportation of cables must be carried out by all types of transport in accordance with the rules for the carriage of goods.
Manufacturer's warranties.
The plant guarantees the quality of the cables complies with the requirements of GOST 1508-78, GOST 26411-85 and
TU 3560-012-55085101-2016, provided that the conditions of operation, storage, and transportation are observed.
Warranty service life is three years from the date the cables are put into operation. The warranty period is calculated from the date the cable is put into operation, but no later than 6 months from the date of manufacture.
| Permissible operating temperature (no movement) to | 50 град.C |
| Permissible operating temperature (without movement) from | -50 град.C |
| Protective grounding conductor | No |
| Core insulation | Polyvinyl chloride (PVC) |
| Conductor class | 1 - single-wire |
| Number of cores | 19 |
| Core marking | Counting pair |
| Oil resistance in accordance with EN 60811-2-1 | No |
| Outer sheath material | Polyvinyl chloride (PVC) |
| Outer diameter (approx.) | 13.7 мм |
| Low smoke emission in accordance with EN 61034-2 (ng-LS version) | Yes |
| Rated voltage U | 660 кВ |
| Rated conductor cross-section | 1 кв.мм |
| Fire resistance | No |
| Recommended installation temperature during pulling, up to | 50 град.C |
| Recommended installation temperature during pulling from | 15 град.C |
| Low temperature resistance in accordance with EN 60811-1-4 | No |
| Outer sheath colour | Black |