Switches are designed for operation in electrical installations with a voltage of up to 690 V AC at 50 and 60 Hz and up to 440 V DC for infrequent (up to 6 times per day) switching and disconnecting of electrical circuits, as well as for protecting electrical equipment from overloads and short circuits, and during voltage drops to an unacceptable level. A3791B — 2-pole DC or AC, current-limiting (application category A) with an electromagnetic maximum current trip unit. A3792B — 3-pole AC, current-limiting (application category A) with an electromagnetic maximum current trip unit. A3793B — 2-pole DC or AC, current-limiting (application category A) with electronic and electromagnetic maximum current trip units. A3794B — 3-pole AC, current-limiting (application category A) with electronic and electromagnetic maximum current trip units. A3793C — 2-pole, selective (application category B) with an electronic maximum current trip unit. A3794C — 3-pole AC, selective (application category B) with an electronic maximum current trip unit. A3797C — 2-pole without maximum current trip units. A3798C — 3-pole without maximum current trip units. Included in the Minpromt register.
Built-in ground fault protection
No
Overload protection device setting range to
440 А
Setting range of overload protection device from
120 А
Instantaneous short-circuit release setting range to
300 А
Instantaneous short-circuit release setting range from
300 А
Trip indicator present
No
Number of auxiliary NO contacts
1
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
0
Number of poles
2
Design
Complete unit in enclosure
Motor drive optional
No
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
35 кА
Rated voltage up to
400 В
Rated voltage from
400 В
Rated continuous current Iu
400 А
Suitable for DIN-rail mounting
No
With minimum voltage protection
No
IP protection rating
IP20
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
1346 ₽
Legrand (группа IEK) DRX125 thermomagnetic 25A 1P 36KA 027042 Legrand
SKU: 027042
4372 ₽
Legrand (группа IEK) Circuit breaker 4p 125A 18kA DRX250 thermomagnetic release Leg 027106 Legrand
SKU: 027106
2652 ₽
КЭАЗ Circuit breaker 1p 0.8A 10In 1.8kA A63 MG U3 400V AC KEAZ 104113
SKU: 104113
2944 ₽
Legrand (группа IEK) Circuit breaker DPX3 160/25A 3P 16kA, TM, Icc=0.8…1In, Ics=10In
SKU: 420001