Контактор (группа IEK)
Circuit breaker A3794БУХЛ3 Output El/Mag 250A 690V 4000A PE220-240AC HP110-440AC VK1Z1R rear connection copper bus IP00 Contactor 1015073
SKU: 1015073
ETIM: EC000228
356,597 ₽
Get back 3,565 ₽ in points
Analogues by specifications
Switches are designed for operation in electrical installations with a voltage of up to 690 V AC at 50 and 60 Hz and up to 440 V DC for infrequent (up to 6 times per day) operational switching of electrical circuits, as well as for protecting electrical equipment from overloads and short circuits, and also during voltage drops to an unacceptable level.
A3791B — 2-pole AC or DC, current-limiting (application category A) with an electromagnetic maximum current trip unit.
A3792B — 3-pole AC, current-limiting (application category A) with an electromagnetic maximum current trip unit.
A3793B — 2-pole AC or DC, current-limiting (application category A) with electronic and electromagnetic maximum current trip units.
A3794B — 3-pole AC, current-limiting (application category A) with electronic and electromagnetic maximum current trip units.
A3793C — 2-pole, selective (application category B) with an electronic maximum current trip unit.
A3794C — 3-pole AC, selective (application category B) with an electronic maximum current trip unit.
A3797C — 2-pole without maximum trip units.
A3798C — 3-pole without maximum trip units.
Included in the Minpromtorg register.
Main circuit connection type
Rear connection
Built-in ground fault protection
Yes
Built-in motor drive
Yes
Height
435.0 мм
Height
435.0 мм
Depth
495.0 мм
Short-time delayed short-circuit release range
112.5…3300 А
Overload protection device setting range to
275 А
Setting range of overload protection device from
75…275 А
Instantaneous short-circuit release setting range to
3300 А
Instantaneous short-circuit release setting range from
150…3300 А
Version
Withdrawable
Design
Withdrawable
Number of auxiliary NO contacts
1
Number of auxiliary break contacts
1
Number of poles
3
Design
Slot-in device (withdrawable)
Motor drive optional
No
Rated service short-circuit breaking capacity Ics
50.5
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
51 кА
Rated voltage up to
690 В
Rated voltage from
0...690 В
Rated current
250 А
Rated continuous current Iu
250 А
Suitable for DIN-rail mounting
No
Power loss
195 Вт
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Main electrical circuit connection type
Screw connection
Control element type
Lever (toggle)
Width
435.0 мм
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
126492 ₽
CHINT Motor protection circuit breaker 3p 500A 50kA NM8N-800S M (R) CHINT 273073
SKU: 273073
637952 ₽
CHINT Air circuit breaker 3p 800A 55kA AC400V type H NA8-1600N-800H/3P drawout (R) CHINT 410992
SKU: 410992
1829878 ₽
CHINT Air circuit breaker NA8-4000H-1600H/4P drawout 1600A 100kA type H AC400V (R) CHINT 262822
SKU: 262822
670023 ₽
CHINT Air circuit breaker 4p 1000A 66kA NA8-1600H-1000M/4P AC 230V type M withdrawable (R) CHINT 520740
SKU: 520740