Контактор (группа IEK)
3p 400A Circuit breaker A3794B UHL3 690V withdrawable manual remote drive Contactor 1037074 Contactor (IEK group)
SKU: 1037074
ETIM: EC000228
333476 ₽
Preorder
Switches are designed for operation in electrical installations with a voltage of up to 690 V AC at 50 and 60 Hz and up to 440 V DC for infrequent (up to 6 times per day) operational switching of electrical circuits, as well as for protecting electrical equipment from overloads and short circuits, and also during voltage drops to an unacceptable level.
A3791B — 2-pole AC or DC, current-limiting (application category A) with an electromagnetic maximum current trip unit.
A3792B — 3-pole AC, current-limiting (application category A) with an electromagnetic maximum current trip unit.
A3793B — 2-pole AC or DC, current-limiting (application category A) with electronic and electromagnetic maximum current trip units.
A3794B — 3-pole AC, current-limiting (application category A) with electronic and electromagnetic maximum current trip units.
A3793C — 2-pole, selective (application category B) with an electronic maximum current trip unit.
A3794C — 3-pole AC, selective (application category B) with an electronic maximum current trip unit.
A3797C — 2-pole without maximum trip units.
A3798C — 3-pole without maximum trip units.
Included in the Minpromtorg register.
| Main circuit connection type | Rear connection |
| Built-in ground fault protection | Yes |
| Built-in motor drive | No |
| Height | 400.0 мм |
| Depth | 460.0 мм |
| Short-time delayed short-circuit release range | 180…5280 А |
| Overload protection device setting range to | 440 А |
| Setting range of overload protection device from | 120 А |
| Instantaneous short-circuit release setting range to | 5280 А |
| Instantaneous short-circuit release setting range from | 240 А |
| Design | Withdrawable |
| Number of auxiliary NO contacts | 1 |
| Number of auxiliary break contacts | 2 |
| Number of poles | 3 |
| Design | Slot-in device (withdrawable) |
| Motor drive optional | No |
| Rated service short-circuit breaking capacity Ics | 50.5 |
| Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz | 51 кА |
| Rated voltage up to | 690 В |
| Rated voltage from | 0 В |
| Rated current | 400 А |
| Rated continuous current Iu | 400 А |
| Suitable for DIN-rail mounting | No |
| Power loss | 195 Вт |
| With minimum voltage protection | Yes |
| IP protection rating | IP00 |
| Product/component type | Moulded case circuit breaker |
| Main electrical circuit connection type | Screw connection |
| Control element type | Extended rotary handle (wide grip) |
| Width | 400.0 мм |
0
★★★★★
0 reviews
No reviews yet. Be the first!