Контактор (группа IEK)
Circuit breaker A3794СУХЛ3 Stac Ruch 250A 690V HP110-220DC VK1Z2R front connection busbar cable with aluminum lug IP20 Contactor 1031866
SKU: 1031866
ETIM: EC000228
253,066 ₽
Get back 2,530 ₽ in points
Analogues by specifications
Switches are designed for operation in electrical installations with a voltage of up to 690 V AC at 50 and 60 Hz and up to 440 V DC for infrequent (up to 6 times per day) switching and disconnecting of electrical circuits, as well as for protecting electrical equipment from overloads and short circuits, and during voltage drops to an unacceptable level. A3791B — 2-pole DC or AC, current-limiting (application category A) with an electromagnetic maximum current trip unit. A3792B — 3-pole AC, current-limiting (application category A) with an electromagnetic maximum current trip unit. A3793B — 2-pole DC or AC, current-limiting (application category A) with electronic and electromagnetic maximum current trip units. A3794B — 3-pole AC, current-limiting (application category A) with electronic and electromagnetic maximum current trip units. A3793C — 2-pole, selective (application category B) with an electronic maximum current trip unit. A3794C — 3-pole AC, selective (application category B) with an electronic maximum current trip unit. A3797C — 2-pole without maximum current trip units. A3798C — 3-pole without maximum current trip units. Included in the Minpromt register.
Built-in ground fault protection
No
Overload protection device setting range to
275 А
Setting range of overload protection device from
75 А
Instantaneous short-circuit release setting range to
2500 А
Instantaneous short-circuit release setting range from
2500 А
Trip indicator present
No
Number of auxiliary NO contacts
2
Number of auxiliary changeover contacts
3
Number of auxiliary break contacts
1
Number of poles
3
Design
Complete unit in enclosure
Motor drive optional
No
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
35 кА
Rated voltage up to
690 В
Rated voltage from
690 В
Rated continuous current Iu
250 А
Suitable for DIN-rail mounting
No
With minimum voltage protection
No
IP protection rating
IP20
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
204347 ₽
CHINT 3P 800A circuit breaker 560…800A range 70kA NM8N-800Q TM with adjustable thermomagnetic release (R) as part of DOB24F-M8 CHINT 272941K1
SKU: 272941K1
2765884 ₽
CHINT Air circuit breaker NA8-7500-6300H/3P withdrawable 6300A 135kA type H DC220V (R) CHINT 262873
SKU: 262873
205579 ₽
CHINT Circuit breaker 3p 400A 70kA NM8N-630Q EM with electr. release LCD (R) CHINT 269481
SKU: 269481
74777 ₽
CHINT Circuit breaker 3p 315A 70kA NM8N-630Q TM with reg. thermomagnetic release (R) CHINT 269264
SKU: 269264
2765884 ₽
CHINT Air circuit breaker NA8-7500-6300H/3P withdrawable 6300A 135kA type H DC220V (R) CHINT 262873
SKU: 262873
205579 ₽
CHINT Circuit breaker 3p 400A 70kA NM8N-630Q EM with electr. release LCD (R) CHINT 269481
SKU: 269481
74777 ₽
CHINT Circuit breaker 3p 315A 70kA NM8N-630Q TM with reg. thermomagnetic release (R) CHINT 269264
SKU: 269264