Контактор (группа IEK)
Circuit breaker AB2M10H-53-41-1000-MP4-10000-UKHL3-2r2z 1000A electr. magnetic trip 10000A; max. current trip MRT4-MP; manual actuator; free contacts 2r2z Contactor 1005839
SKU: 1005839
ETIM: EC000228
462,375 ₽
Get back 4,623 ₽ in points
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Front connection
Built-in ground fault protection
No
Built-in motor drive
No
Depth
190.0 мм
Short-time delayed short-circuit release range
360…12000 А
Overload protection device setting range to
1100 А
Setting range of overload protection device from
300…1000 А
Instantaneous short-circuit release setting range to
16000 А
Instantaneous short-circuit release setting range from
4000 А
Design
Stationary
Climatic version
UKhL3
Number of auxiliary NO contacts
2
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
2
Number of poles
3
Design
Built-in device for built-in appliances
Motor drive optional
No
Electronic release available
Yes
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
1000 А
Rated continuous current Iu
1000 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Main electrical circuit connection type
Bolted connection
Control element type
Lever (toggle)
Mains supply frequency
50/60 Гц
Width
405.0 мм
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
553280 ₽
CHINT Air circuit breaker NA8-1600N-630M/4P drawout 630A 55kA type M AC230V (R) CHINT 404712
SKU: 404712
3072077 ₽
CHINT Air circuit breaker NA8-4000HU-4000H/4P drawout 4000A 75kA type H AC 230V (R) CHINT 404675
SKU: 404675
80095 ₽
CHINT Motor protection circuit breaker 3p 350A 70kA NM8N-630Q M (R) CHINT 269530
SKU: 269530
136997 ₽
CHINT Circuit breaker NM8N-250HVS TM 3p 180A 50kA with reg. thermomagnetic release (R) CHINT 367776
SKU: 367776