Контактор (группа IEK)
Circuit breaker АВ2М10Н-53-41-1000-МР4-10000-УХЛ3-РНН220ВAC-2р2з 1000A magnetic trip 10000A; max current trip MРT4-МП; min voltage trip 220V AC; manual drive; free contacts 2p2r 1000A Contactor 1027575
SKU: 1027575
ETIM: EC000228
462,375 ₽
Get back 4,623 ₽ in points
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Front connection
Built-in ground fault protection
No
Built-in motor drive
No
Depth
190.0 мм
Short-time delayed short-circuit release range
360…12000 А
Overload protection device setting range to
1100 А
Setting range of overload protection device from
300…1000 А
Version
Stationary
Climatic version
UKhL3
Number of auxiliary NO contacts
2
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
2
Number of poles
3
Design
Built-in device for built-in appliances
Motor drive optional
No
Electronic release available
Yes
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
1000 А
Rated continuous current Iu
1000 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Main electrical circuit connection type
Bolted connection
Control element type
Lever (toggle)
Mains supply frequency
50/60 Гц
Width
405.0 мм
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
8691 ₽
CHINT Circuit breaker NM8N-125C TM 1p 25A 36kA with reg. thermomagnetic release (R) CHINT 271513
SKU: 271513
238528 ₽
CHINT Motor protection circuit breaker 3p 700A 150kA NM8N-800R M (R) CHINT 273087
SKU: 273087
34883 ₽
CHINT Circuit breaker 2p 180A 150kA NM8N-250R TM with reg. thermomagnetic release (R) CHINT 271239
SKU: 271239
23163 ₽
CHINT Circuit breaker 2p 20A 150kA NM8N-125R TM with reg. thermomagnetic release (R) CHINT 271692
SKU: 271692