Контактор (группа IEK)
Circuit breaker АВ2М10Н-53-41-800-МР4-10000-УХЛ3-НР230ВAC-2р2з 800A magnetic trip 10000A; max current trip unit МРТ4-МП; shunt trip 230V AC; manual drive; free contacts 2p2r 800A Contactor 1004867
SKU: 1004867
ETIM: EC000228
462,375 ₽
Get back 4,623 ₽ in points
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Front connection
Built-in ground fault protection
No
Built-in motor drive
No
Depth
190.0 мм
Short-time delayed short-circuit release range
288…9600 А
Overload protection device setting range to
880 А
Setting range of overload protection device from
240…800 А
Auxiliary device factory-installed
Shunt release (for power circuit breakers)
Design
Stationary
Climatic version
UKhL3
Number of auxiliary NO contacts
2
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
2
Number of poles
3
Design
Built-in device for built-in appliances
Motor drive optional
No
Electronic release available
Yes
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
800 А
Rated continuous current Iu
800 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Main electrical circuit connection type
Bolted connection
Control element type
Lever (toggle)
Mains supply frequency
50/60 Гц
Width
405.0 мм
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
204906 ₽
CHINT Circuit breaker 3p 700A 100kA NM8NDC-800H TM with reg. thermomagnetic trip (R) CHINT 272992
SKU: 272992
10162 ₽
CHINT Circuit breaker NM8N-125S TM 1p 40A 50kA with reg. thermomagnetic release (R) CHINT 271565
SKU: 271565
2765884 ₽
CHINT Air circuit breaker NA8-7500-6300H/3P drawout 6300A 135kA type H AC400V (R) CHINT 262869
SKU: 262869
114321 ₽
CHINT Circuit breaker 4p 400A 100kA NM8N-630H TM with reg. thermomagnetic release (R) CHINT 269291
SKU: 269291