Контактор (группа IEK)
Circuit breaker AV2M10N-53-41-800-MP4-10000-UKHL3-NR380VAC-PE220VAC-3p3w 800A magnetic trip 10000A; max current trip MRT4-MP; independent trip 380VAC; magnetic drive 220VAC; free contacts 3p3w Contactor 1023547
SKU: 1023547
ETIM: EC000228
526,169 ₽
Get back 5,261 ₽ in points
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Front connection
Built-in ground fault protection
No
Built-in motor drive
Yes
Depth
297.0 мм
Short-time delayed short-circuit release range
288…9600 А
Overload protection device setting range to
880 А
Setting range of overload protection device from
240…800 А
Design
Stationary
Climatic version
UKhL3
Number of auxiliary NO contacts
3
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
3
Number of poles
3
Design
Built-in device for built-in appliances
Motor drive optional
Yes
Electronic release available
Yes
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
800 А
Rated continuous current Iu
800 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Main electrical circuit connection type
Bolted connection
Control element type
Other
Mains supply frequency
50/60 Гц
Width
405.0 мм
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
206007 ₽
CHINT Automatic circuit breaker 4p 1000A 50kA NM8N-1600S TM with thermomagnetic release (R) CHINT 263079
SKU: 263079
57134 ₽
CHINT Automatic circuit breaker for motor protection 3p 400A 50kA NM8N-400S M CHINT 269505
SKU: 269505
97219 ₽
CHINT Molded Case Circuit Breaker 4p 200A 50kA NM8NDC-250S TM with thermomagnetic release (R) CHINT 271306
SKU: 271306
352665 ₽
CHINT Molded Case Circuit Breaker 3p 1000A 100kA NM8N-1600H EN with electric release MP 400 AC (R) CHINT 263263
SKU: 263263