Контактор (группа IEK)
Molded case circuit breaker AV2M10H-53-41-800-MP4-10000-UHL3-RNN220VAC-2p2r 800A magnetic release 10000A; max release current MRT4-MP; min voltage release 220VAC; manual drive; free contacts 2p2r Contactor 1035019
SKU: 1035019
ETIM: EC000228
624,812 ₽
Get back 6,248 ₽ in points
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Rear connection
Built-in ground fault protection
No
Built-in motor drive
No
Height
500.0 мм
Short-time delayed short-circuit release range
288…9600 А
Overload protection device setting range to
880 А
Setting range of overload protection device from
240…800 А
Design
Withdrawable
Climatic version
UKhL3
Number of auxiliary NO contacts
2
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
2
Number of poles
3
Design
Slot-in device (withdrawable)
Motor drive optional
No
Electronic release available
Yes
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
800 А
Rated continuous current Iu
800 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Control element type
Extended rotary handle (wide grip)
Mains supply frequency
50/60 Гц
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
3801208 ₽
CHINT Air circuit breaker NA8-7500-6300H/4P trip 6300A 135kA type H DC220V (R) CHINT 262894
SKU: 262894
203016 ₽
CHINT Circuit breaker NM8NDC-1600B TM 3p 800A 25kA with thermomagnetic release (R) CHINT 263154
SKU: 263154
6848 ₽
CHINT Circuit breaker 3p 40A 25kA NXM-63S (R) CHINT 205887
SKU: 205887
1072499 ₽
CHINT Air circuit breaker NA8-2500H-2000M/4P drawout 2000A 85kA type M AC230V (R) CHINT 262561
SKU: 262561