Контактор (группа IEK)
Automatic circuit breaker АВ2М10С-55-41-800-МР4-УХЛ3-РНН220ВAC-ПЭ220ВAC-1р2з 800A; max current trip unit МРТ4-МП; min voltage trip 220V AC; electromagnetic drive 220V AC; free contacts 1p2z Contactor 1026472
SKU: 1026472
ETIM: EC000228
541,657 ₽
Get back 5,416 ₽ in points
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Front connection
Built-in ground fault protection
No
Built-in motor drive
Yes
Depth
297.0 мм
Overload protection device setting range to
880 А
Setting range of overload protection device from
240…880 А
Instantaneous short-circuit release setting range to
12800 А
Instantaneous short-circuit release setting range from
3200 А
Design
Stationary
Climatic version
UKhL3
Number of auxiliary NO contacts
2
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
1
Number of poles
3
Design
Built-in device for built-in appliances
Motor drive optional
Yes
Electronic release available
Yes
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
800 А
Rated continuous current Iu
800 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Main electrical circuit connection type
Bolted connection
Control element type
Other
Mains supply frequency
50/60 Гц
Width
405.0 мм
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
23163 ₽
CHINT Circuit breaker 2p 40A 150kA NM8N-125R TM with reg. thermomagnetic trip (R) CHINT 271695
SKU: 271695
22930 ₽
CHINT Molded circuit breaker NM8NDC-125S TM 1p 50A 50kA with thermomagnetic trip (R) CHINT 330519
SKU: 330519
1745489 ₽
CHINT Air circuit breaker NA8-4000H-3200H/3P stac. 3200A 100kA type H DC220V (R) CHINT 262757
SKU: 262757
31146 ₽
CHINT Circuit breaker 3p 200A 36kA NXMS-250F with elec. trip (R) CHINT 264754
SKU: 264754