Контактор (группа IEK)
Circuit breaker AB2M10SV-55-41-800-MR4-UHL3-NR220VDC-PE220VAC 800A elec.mag. release A; max. current release MRT4-MP; non-trip release 220VDC; elec.mag. drive 220VAC Contactor 1015081
SKU: 1015081
ETIM: EC000228
640,467 ₽
Get back 6,404 ₽ in points
Promo code
FIRST
— cashback ×3 on your first order: 3% in points on the first 50,000 ₽
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Rear connection
Built-in ground fault protection
No
Built-in motor drive
Yes
Height
500.0 мм
Short-time delayed short-circuit release range
288…9600 А
Overload protection device setting range to
880 А
Setting range of overload protection device from
240…800 А
Design
Withdrawable
Climatic version
UKhL3
Number of auxiliary NO contacts
2
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
2
Number of poles
3
Design
Slot-in device (withdrawable)
Motor drive optional
Yes
Electronic release available
Yes
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
800 А
Rated continuous current Iu
800 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Control element type
Other
Mains supply frequency
50/60 Гц
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
4676 ₽
КЭАЗ AE2043M-400-2,5A-12In-400AC-U3
SKU: 104600
3235 ₽
Legrand (группа IEK) Circuit breaker DPX³ 160 - thermal-magnetic release - 36 kA - 400 V AC - 3P - 40 A 420082 Legrand
SKU: 420082
3331 ₽
КЭАЗ Circuit breaker 1p 16A 2Iн 1.8kA A63 M XL3 110V DC KEAZ 103969
SKU: 103969
4319 ₽
Legrand (группа IEK) 423131, ACB DPX³ 250HP TM 3P 200A 70kA Legrand
SKU: 423131