Контактор (группа IEK)
Circuit breaker AB2M15-56-43-1500-UHL3-NR220VDC-PE220VAC-3r3z 1500A; without max current elec. trip; independent trip 220VDC; magnetic drive 220VAC; free contacts 3r3z Contactor 1040703
SKU: 1040703
ETIM: EC000228
685,219 ₽
Get back 6,852 ₽ in points
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Front connection
Built-in ground fault protection
No
Built-in motor drive
Yes
Depth
320.0 мм
Overload protection device setting range to
1650 А
Setting range of overload protection device from
450 А
Design
Stationary
Climatic version
UKhL3
Number of auxiliary NO contacts
3
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
3
Number of poles
3
Design
Built-in device for built-in appliances
Motor drive optional
Yes
Electronic release available
No
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
1500 А
Rated continuous current Iu
1500 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Main electrical circuit connection type
Bolted connection
Control element type
Other
Width
500.0 мм
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
64628 ₽
CHINT Circuit breaker 4p 100A 50kA NM8N-250S EN with elec. release (R) CHINT 271338
SKU: 271338
270367 ₽
CHINT Molded case circuit breaker 4p 800A 70kA NM8N-800Q EN with elec. trip (R) CHINT 273040
SKU: 273040
159242 ₽
CHINT Molded Case Circuit Breaker 3p 250A 50kA NM8N-400S EM with LCD electric release (R) CHINT 269452
SKU: 269452
25372 ₽
CHINT Motor protection circuit breaker 3p 32A 100kA NM8N-125H M (R) CHINT 271864
SKU: 271864