Контактор (группа IEK)
Automatic circuit breaker АВ2М15С-55-43-1200-МР4-УХЛ3-НР220ВDC-ПЭ220ВDC-3p3z 1200A; max current trip unit МРТ4-МП; independent trip coil 220VDC; electromagnetic drive 220VDC; free contacts 3p3z Contactor 1031050
SKU: 1031050
ETIM: EC000228
586,570 ₽
Get back 5,865 ₽ in points
Promo code
FIRST
— cashback ×3 on your first order: 3% in points on the first 50,000 ₽
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Built-in ground fault protection
No
Overload protection device setting range to
1320 А
Setting range of overload protection device from
360 А
Instantaneous short-circuit release setting range to
14 А
Instantaneous short-circuit release setting range from
14 А
Trip indicator present
No
Number of auxiliary NO contacts
0
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
0
Number of poles
3
Design
Built-in fixed-mounted device
Motor drive optional
No
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
.6 кА
Rated voltage up to
400 В
Rated voltage from
220 В
Rated continuous current Iu
1200 А
Suitable for DIN-rail mounting
No
With minimum voltage protection
No
IP protection rating
IP20
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
3331 ₽
КЭАЗ Circuit breaker 1p 10A 1.3Icn 2.5kA A63 M HL3 110V DC KEAZ 103924
SKU: 103924
1864 ₽
Legrand (группа IEK) Circuit breaker 3p 60A 36kA DRX125 stationary Leg 027066 Legrand
SKU: 027066
4227 ₽
КЭАЗ Circuit breaker 2p 4A 10In 0.6kA AP50B 2M U3 400V AC/220V DC KEAZ 106464
SKU: 106464
5488 ₽
КЭАЗ Circuit breaker 3P 40A 400Im 40kA VA57-31-340010 UHL3 690V AC KEAZ 108434
SKU: 108434