Контактор (группа IEK)
Automatic circuit breaker АВ2М15С-55-43-1200-МР4-УХЛ3-НР220ВDC-ПЭ220ВDC-3p3z 1200A; max current trip unit МРТ4-МП; independent trip coil 220VDC; electromagnetic drive 220VDC; free contacts 3p3z Contactor 1031050
SKU: 1031050
ETIM: EC000228
685,245 ₽
Get back 6,852 ₽ in points
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Built-in ground fault protection
No
Overload protection device setting range to
1320 А
Setting range of overload protection device from
360 А
Instantaneous short-circuit release setting range to
14 А
Instantaneous short-circuit release setting range from
14 А
Trip indicator present
No
Number of auxiliary NO contacts
0
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
0
Number of poles
3
Design
Built-in fixed-mounted device
Motor drive optional
No
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
It appears your message contains only ".6". Please provide the text you would like me to translate from Russian to English, and I will follow your instructions strictly. кА
Rated voltage up to
400 В
Rated voltage from
220 В
Rated continuous current Iu
1200 А
Suitable for DIN-rail mounting
No
With minimum voltage protection
No
IP protection rating
IP20
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
80511 ₽
CHINT Circuit breaker 4p 32A 100kA NM8NDC-125H TM with reg. thermomagnetic trip (R) CHINT 271824
SKU: 271824
3435454 ₽
CHINT Air circuit breaker NA8-7500-5000M/4P trip 5000A 135kA type M DC220V (R) CHINT 111622
SKU: 111622
3244658 ₽
CHINT Air circuit breaker 3p 5000A 150kA NA8-7500H-5000S/3P AC 400V type S withdrawable (R) CHINT 539440
SKU: 539440
1029545 ₽
CHINT Air circuit breaker 4p 1250A 55kA NA8-1600N-1250S/4P AC 230V type S withdrawable (R) CHINT 530563
SKU: 530563