Контактор (группа IEK)
Circuit breaker AB2M15C-55-43-1200-MP4-UKHL3-NR380VAC-PE220VAC-3p3z 1200A; max trip unit MRT4-MP; shunt trip 380VAC; electromagnetic drive 220VAC; free contacts 3p3z Contactor 1029771
SKU: 1029771
ETIM: EC000228
685,245 ₽
Get back 6,852 ₽ in points
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Front connection
Built-in ground fault protection
No
Built-in motor drive
Yes
Depth
320.0 мм
Short-time delayed short-circuit release range
432…15840 А
Overload protection device setting range to
1320 А
Setting range of overload protection device from
360…1320 А
Instantaneous short-circuit release setting range to
150 А
Instantaneous short-circuit release setting range from
150 А
Trip indicator present
No
Design
Stationary
Climatic version
UKhL3
Number of auxiliary NO contacts
3
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
3
Number of poles
3
Design
Built-in device for built-in appliances
Motor drive optional
Yes
Electronic release available
Yes
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage up to
440 В
Rated voltage from
0...690 В
Rated current
1200 А
Rated continuous current Iu
1200 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Main electrical circuit connection type
Bolted connection
Control element type
Other
Mains supply frequency
50/60 Гц
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
26555 ₽
CHINT Circuit breaker 4p 32A 50kA NM8N-125S TM with reg. thermomagnetic release (R) CHINT 271604
SKU: 271604
36336 ₽
CHINT Molded Case Circuit Breaker 3p 160A 100kA NM8N-250H TM with reg. thermomagnetic release (R) CHINT 271220
SKU: 271220
22013 ₽
CHINT Circuit breaker 2p 32A 36kA NM8NDC-125C TM with reg. thermomagnetic trip (R) CHINT 275588
SKU: 275588
45285 ₽
CHINT Motor protection circuit breaker 3p 160A 70kA NM8N-250Q ENM (R) CHINT 271464
SKU: 271464