Контактор (группа IEK)
Automatic circuit breaker АВ2М15С-55-43-1500-МР1-УХЛ3-НР220ВDC-ПЭ220ВDC-3p3z 1500A; stationary; max current trip unit МРТ1-МП; independent trip unit 220VDC; electromagnetic drive 220VDC; free contacts 3p3z Contactor 1046393
SKU: 1046393
ETIM: EC000228
685,245 ₽
Get back 6,852 ₽ in points
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Front connection
Built-in ground fault protection
No
Built-in motor drive
Yes
Depth
320.0 мм
Setting range of overload protection device from
450…1500 А
Version
Stationary
Climatic version
UKhL3
Number of auxiliary NO contacts
3
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
3
Number of poles
3
Design
Built-in device for built-in appliances
Motor drive optional
Yes
Electronic release available
Yes
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
1500 А
Rated continuous current Iu
1500 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Main electrical circuit connection type
Bolted connection
Control element type
Other
Mains supply frequency
50/60 Гц
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
3387777 ₽
CHINT Air circuit breaker NA8-7500H-7500H/3P trip 7500A 150kA type H AC400V (R) CHINT 262915
SKU: 262915
810846 ₽
CHINT Molded Case Circuit Breaker 4p 1600A 70kA NM8N-1600Q EM with LCD electronic trip unit 230 AC (R) CHINT 263341
SKU: 263341
48610 ₽
CHINT Circuit breaker 2p 200A 50kA NM8NDC-250S TM with reg. thermomagnetic trip (R) CHINT 274859
SKU: 274859
200269 ₽
CHINT Motor protection circuit breaker 3p 800A 100kA NM8N-800H EMM LCD (R) CHINT 273106
SKU: 273106