Контактор (группа IEK)
Circuit breaker AV2M15SV-55-43-1200-MP1-UKHL3-NR220VAC-PE220VAC-3p3w 1200A; max trip current MP1-MP; undervoltage release 220VAC; electromagnetic drive 220VAC; free contacts 3p3w Contactor 1044663
SKU: 1044663
ETIM: EC000228
866,040 ₽
Get back 8,660 ₽ in points
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Rear connection
Built-in ground fault protection
No
Built-in motor drive
Yes
Setting range of overload protection device from
360…1320 А
Design
Withdrawable
Climatic version
UKhL3
Number of auxiliary NO contacts
3
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
3
Number of poles
3
Design
Slot-in device (withdrawable)
Motor drive optional
Yes
Electronic release available
Yes
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
1200 А
Rated continuous current Iu
1200 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Control element type
Other
Mains supply frequency
50/60 Гц
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
3801208 ₽
CHINT Air circuit breaker NA8-7500-7500H/4P withdrawable 7500A 135kA type H AC230V (R) CHINT 262887
SKU: 262887
1831292 ₽
CHINT Air circuit breaker 3p 1600A 75kA NA8-4000HU-1600S/3P AC 230V type S stac. (R) CHINT 530676
SKU: 530676
99875 ₽
CHINT Molded Case Circuit Breaker 3p 630A 36kA NM8N-630C EN 3P with electronic trip unit CHINT 269420
SKU: 269420
816092 ₽
CHINT Air circuit breaker NA8-2500H-1000M/3P drawout 1000A 85kA type M AC400V (R) CHINT 262447
SKU: 262447