Контактор (группа IEK)
Circuit breaker AB2M15SV-55-43-1200-MP4-UKHL3-HP500VAC-PE220VAC-3p4z 1200A; max trip current release MRT4-MP; independent release 500VAC; electromagnetic drive 220VAC; free contacts 3p4z Contactor 1023713
SKU: 1023713
ETIM: EC000228
866,040 ₽
Get back 8,660 ₽ in points
Promo code
FIRST
— cashback ×3 on your first order: 3% in points on the first 50,000 ₽
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Rear connection
Built-in ground fault protection
No
Built-in motor drive
Yes
Short-time delayed short-circuit release range
432…15840 А
Overload protection device setting range to
1320 А
Setting range of overload protection device from
360…1320 А
Version
Withdrawable
Design
Withdrawable
Climatic version
UKhL3
Number of auxiliary NO contacts
4
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
3
Number of poles
3
Design
Slot-in device (withdrawable)
Motor drive optional
Yes
Electronic release available
Yes
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
1200 А
Rated continuous current Iu
1200 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Control element type
Other
Mains supply frequency
50/60 Гц
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
3841 ₽
ELTEC Circuit breaker VA 30-35 3P 125A ELTEC 1135125
SKU: 1135125
4498 ₽
Эра Circuit breaker ВА88-32М PRO SVA10-3-0016-E 3P 16A 25kA Era Б0051906
SKU: Б0051906
5111 ₽
КЭАЗ Circuit breaker 3P 100A 1000Im 15kA VA57F35-340010 UHL3 400V AC KEAZ 109286
SKU: 109286
3985 ₽
КЭАЗ Circuit breaker 3p 4A 10kA 0.6kA AP50B 3MT U3 400V AC additional contacts 2switches KEAZ 107313
SKU: 107313
4498 ₽
Эра Circuit breaker ВА88-32М PRO SVA10-3-0016-E 3P 16A 25kA Era Б0051906
SKU: Б0051906
5111 ₽
КЭАЗ Circuit breaker 3P 100A 1000Im 15kA VA57F35-340010 UHL3 400V AC KEAZ 109286
SKU: 109286
3985 ₽
КЭАЗ Circuit breaker 3p 4A 10kA 0.6kA AP50B 3MT U3 400V AC additional contacts 2switches KEAZ 107313
SKU: 107313