Контактор (группа IEK)
Automatic circuit breaker AB2M15V-56-43-1200-UKHL3-HP220VAC-PE220VDC-3p3z 1200A; without max current trip unit; independent trip unit 220VAC; electromagnetic drive 220VDC; free contacts 3p3z Contactor 1038900
SKU: 1038900
ETIM: EC000228
1,011,678 ₽
Get back 10,116 ₽ in points
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Rear connection
Built-in ground fault protection
No
Built-in motor drive
Yes
Overload protection device setting range to
1320 А
Setting range of overload protection device from
360 А
Design
Withdrawable
Climatic version
UKhL3
Number of auxiliary NO contacts
3
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
3
Number of poles
3
Design
Slot-in device (withdrawable)
Motor drive optional
Yes
Electronic release available
No
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
1200 А
Rated continuous current Iu
1200 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Control element type
Other
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
1092035 ₽
CHINT Air circuit breaker NA8-4000H-2500M/4P stat. 2500A 100kA type M AC400V (R) CHINT 262784
SKU: 262784
95188 ₽
CHINT Automatic circuit breaker 3p 800A 36kA NM8N-800C TM with thermomagnetic release (R) CHINT 272917
SKU: 272917
1123430 ₽
CHINT Air circuit breaker NA8-2500H-1250H/3P stac. 1250A 85kA type H AC400V (R) CHINT 262514
SKU: 262514
707812 ₽
CHINT Air circuit breaker 4p 1250A 66kA NA8-1600H-1250M/4P AC 400V type M withdrawable (R) CHINT 537258
SKU: 537258