Контактор (группа IEK)
Automatic circuit breaker АВ2М20НВ-53-43-1500-МР4-12500-УХЛ3-НР500ВAC-ПЭ220ВAC-3р3з 1500A elect. magnetic trip 12500A; max current trip МРТ4-МП; independent trip 500VAC; elect. magnetic drive 220VAC; free contacts 3p3z Contactor 1021310
SKU: 1021310
ETIM: EC000228
1,280,523 ₽
Get back 12,805 ₽ in points
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Rear connection
Built-in ground fault protection
No
Built-in motor drive
Yes
Short-time delayed short-circuit release range
540…18000 А
Overload protection device setting range to
1650 А
Setting range of overload protection device from
450…1500 А
Instantaneous short-circuit release setting range to
24000 А
Instantaneous short-circuit release setting range from
6000 А
Design
Withdrawable
Climatic version
UKhL3
Number of auxiliary NO contacts
3
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
3
Number of poles
3
Design
Slot-in device (withdrawable)
Motor drive optional
Yes
Electronic release available
Yes
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
1500 А
Rated continuous current Iu
1500 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Control element type
Other
Mains supply frequency
50/60 Гц
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
1489199 ₽
CHINT Air circuit breaker 3p 1000A 85kA NA8-2500H-1000S/3P AC 400V type S drawout (R) CHINT 532461
SKU: 532461
1030852 ₽
CHINT Air circuit breaker NA8-2500H-1250M/4P drawout 1250A 85kA type M AC230V (R) CHINT 262555
SKU: 262555
2280791 ₽
CHINT Air circuit breaker NA8-4000HU-4000M/3P drawout 4000A 75kA type M AC 230V (R) CHINT 396417
SKU: 396417
139076 ₽
CHINT Motor protection circuit breaker 3p 630A 70kA NM8N-630Q EMM LCD (R) CHINT 269586
SKU: 269586