Контактор (группа IEK)
Circuit breaker АВ2М20В-56-43-2000-УХЛ3-НР380ВAC-ПЭ220ВAC-3р3з 2000A; without max. current elec. trip unit; independent trip unit 380V AC; electromagnetic drive 220V AC; free contacts 3p3z Contactor 1046096
SKU: 1046096
ETIM: EC000228
1,280,523 ₽
Get back 12,805 ₽ in points
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Rear connection
Built-in ground fault protection
No
Built-in motor drive
Yes
Design
Withdrawable
Climatic version
UKhL3
Number of auxiliary NO contacts
3
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
3
Number of poles
3
Design
Slot-in device (withdrawable)
Motor drive optional
Yes
Electronic release available
No
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
2000 А
Rated continuous current Iu
2000 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Control element type
Other
Mains supply frequency
50/60 Гц
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
775287 ₽
CHINT Air circuit breaker NA8-2500H-800M/3P drawout 800A 85kA type M AC230V (R) CHINT 262423
SKU: 262423
615489 ₽
CHINT Air circuit breaker NA8-1600N-1250M/4P drawout 1250A 55kA type M AC230V (R) CHINT 404715
SKU: 404715
857956 ₽
CHINT Air circuit breaker 3p 1250A 55kA NA8-1600N-1250S/3P AC 400V type S withdrawable (R) CHINT 530569
SKU: 530569
34883 ₽
CHINT Circuit breaker 2p 180A 150kA NM8N-250R TM with reg. thermomagnetic release (R) CHINT 271239
SKU: 271239