Контактор (группа IEK)
Circuit breaker AV2M4NV-53-41-250-MP4-4000-UHL3-NR220VDC-PE220VDC-3p3z 250A magnetic trip 4000A; max current trip unit MRT4-MP; independent trip unit 220VDC; electromagnetic drive 220VDC; free contacts 3p3z Contactor 1039859
SKU: 1039859
ETIM: EC000228
734,116 ₽
Get back 7,341 ₽ in points
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Rear connection
Built-in ground fault protection
No
Built-in motor drive
Yes
Height
500.0 мм
Short-time delayed short-circuit release range
90…3300 А
Overload protection device setting range to
275 А
Setting range of overload protection device from
75…275 А
Design
Withdrawable
Climatic version
UKhL3
Number of auxiliary NO contacts
3
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
3
Number of poles
3
Design
Slot-in device (withdrawable)
Motor drive optional
Yes
Electronic release available
Yes
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
250 А
Rated continuous current Iu
250 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Control element type
Other
Mains supply frequency
50/60 Гц
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
50446 ₽
CHINT Circuit breaker 3p 40A 70kA NM8NDC-125Q TM with reg. thermomagnetic release (R) CHINT 271765
SKU: 271765
63796 ₽
CHINT Circuit breaker 3p 315A 50kA NM8N-400S TM with adjustable thermomagnetic trip unit CHINT 268948
SKU: 268948
786190 ₽
CHINT Air circuit breaker 3p 1000A 55kA NA8-1600N-1000S/3P AC 230V type S withdrawable (R) CHINT 530545
SKU: 530545
1168816 ₽
CHINT Air circuit breaker NA8-2500H-2000H/3P stac. 2000A 85kA type H AC230V (R) CHINT 262499
SKU: 262499