Контактор (группа IEK)
Circuit breaker АВ2М4С-55-41-250-МР2-УХЛ3-НР220ВAC-ПЭ220ВAC-3р3з 250A; max current trip unit МРТ2-МП; independent trip unit 220V AC; electromagnetic drive 220V AC; free contacts 3p3z Contactor 1046212
SKU: 1046212
ETIM: EC000228
616,985 ₽
Get back 6,169 ₽ in points
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Front connection
Built-in ground fault protection
No
Built-in motor drive
Yes
Depth
297.0 мм
Short-time delayed short-circuit release range
112.5…3300 А
Setting range of overload protection device from
75…275 А
Instantaneous short-circuit release setting range from
150…3300 А
Design
Stationary
Climatic version
UKhL3
Number of auxiliary NO contacts
3
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
3
Number of poles
3
Design
Built-in device for built-in appliances
Motor drive optional
Yes
Electronic release available
Yes
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
250 А
Rated continuous current Iu
250 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Main electrical circuit connection type
Bolted connection
Control element type
Other
Mains supply frequency
50/60 Гц
Width
405.0 мм
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
16977 ₽
CHINT Circuit breaker 4p 100A 36kA NM8N-125C TM with reg. thermomagnetic trip (R) CHINT 271559
SKU: 271559
822208 ₽
CHINT Air circuit breaker 3p 1250A 66kA NA8-1600H-1250H/3P AC 230V type H draw-out (R) CHINT 533215
SKU: 533215
17610 ₽
CHINT Circuit breaker 2p 50A 25kA NM8NDC-125B TM with reg. thermomagnetic trip (R) CHINT 275580
SKU: 275580
986649 ₽
CHINT Air circuit breaker 3p 1250A 66kA NA8-1600H-1250S/3P AC 400V type S draw-out (R) CHINT 530570
SKU: 530570