Контактор (группа IEK)
Automatic circuit breaker AB2M20C-55-43-2000-MP4-UHL3-NR220VAC-PE220VAC-3p3z 2000A; max. current trip unit MRT4-MP; undervoltage release 220VAC; electromagnetic drive 220VAC; free contacts 3p3z Contactor 1002010
SKU: 1002010
ETIM: EC000228
781,780 ₽
Get back 7,817 ₽ in points
Promo code
FIRST
— cashback ×3 on your first order: 3% in points on the first 50,000 ₽
Analogues by specifications
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Front connection
Built-in ground fault protection
No
Built-in motor drive
Yes
Depth
500.0 мм
Short-time delayed short-circuit release range
720…24000 А
Overload protection device setting range to
2000 А
Setting range of overload protection device from
600…2000 А
Instantaneous short-circuit release setting range to
30000 А
Instantaneous short-circuit release setting range from
30000…30000 А
Version
Stationary
Design
Stationary
Number of auxiliary NO contacts
0
Number of auxiliary break contacts
0
Number of poles
3
Design
Device complete with housing
Motor drive optional
No
Rated service short-circuit breaking capacity Ics
35
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
35 кА
Rated voltage up to
690 В
Rated voltage from
0...690 В
Rated current
2000 А
Rated continuous current Iu
2000 А
Suitable for DIN-rail mounting
No
Power loss
600 Вт
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Main electrical circuit connection type
Screw connection
Control element type
Lever (toggle)
Width
880.0 мм
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
3869 ₽
Legrand (группа IEK) 669026, DRX 250HP TM adj. 4P 63A, 25kA Legrand