Контактор (группа IEK)
Circuit breaker АВ2М10С-55-41-800-МР4-УХЛ3-НР220ВAC-2р1з 800A; max current trip unit МРТ4-МП; shunt trip 220V AC; manual drive; free contacts 2p1z Contactor 1003390
SKU: 1003390
ETIM: EC000228
388,175 ₽
Get back 3,881 ₽ in points
Promo code
FIRST
— cashback ×3 on your first order: 3% in points on the first 50,000 ₽
Analogues by specifications
Stock by warehouse
Switches are intended to replace the AVM series circuit breakers in operation and are manufactured based on the VA50-41 and VA50-43 series switches. The switches are used in AC electrical circuits with a rated voltage of up to 660 V at a frequency of 50 or 60 Hz for conducting current in normal mode and disconnecting during short circuits and overloads, as well as for infrequent (up to 10 times per day) operational switching of these circuits. The series is included in the list of domestic products according to RF Decree No. 719 (Ministry of Industry and Trade register).
AV2M4N-53-41 – non-selective for rated currents 250 and 400 A
AV2M4S-55-41 – selective for rated currents 250 and 400 A
AV2M10N-53-41 – non-selective for rated currents 800 and 1000 A
AV2M10S-55-41 – selective for rated currents 800 and 1000 A
AV2M15N-53-43 – non-selective for rated currents 1200 and 1500 A.
AV2M15S-55-43 – selective for rated currents 1200 and 1500 A.
AV2M20N-53-43 – non-selective for rated currents 1500 and 2000 A.
AV2M20S-55-43 – selective for rated currents 1500 and 2000 A.
AV2M4-56-41 – without maximum current trips for rated current 400 A.
AV2M10-56-41 - without maximum current trips for rated currents 800 and 1000 A.
AV2M15-56-43 – without maximum current trips for rated currents 1200 and 1500 A.
AV2M20-56-43 - without maximum current trips for rated currents 1500 and 2000 A.
Main circuit connection type
Front connection
Built-in ground fault protection
No
Built-in motor drive
No
Depth
190.0 мм
Overload protection device setting range to
880 А
Setting range of overload protection device from
240…880 А
Instantaneous short-circuit release setting range to
12800 А
Instantaneous short-circuit release setting range from
3200 А
Auxiliary device factory-installed
Shunt release (for power circuit breakers)
Design
Stationary
Climatic version
UKhL3
Number of auxiliary NO contacts
1
Number of auxiliary changeover contacts
0
Number of auxiliary break contacts
2
Number of poles
3
Design
Built-in device for built-in appliances
Motor drive optional
No
Electronic release available
Yes
Rated impulse withstand voltage
6
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
23 кА
Rated voltage
690 В
Rated voltage from
0...690 В
Rated current
800 А
Rated continuous current Iu
800 А
Suitable for DIN-rail mounting
No
Power loss
348 Вт
With minimum voltage protection
Yes
Tripping system
Electronic
IP protection rating
IP00
Product/component type
Moulded case circuit breaker
Main electrical circuit connection type
Bolted connection
Control element type
Lever (toggle)
Mains supply frequency
50/60 Гц
Width
405.0 мм
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
3958 ₽
КЭАЗ Circuit breaker 3p 25A 10I 3kA AP50B 3MT U3 AES 400V AC KEAZ 107277
SKU: 107277
567 ₽
Электротехник Circuit breaker 16...25A J2 APD 80-ZMT-UZ Elektrotekhnik ET051676
SKU: ET051676
5377 ₽
КЭАЗ Miniature circuit breaker 1p 1.6A 1.5In 6kA VA21-29-120010 U3 400V AC KEAZ 101236
SKU: 101236
5111 ₽
КЭАЗ Circuit breaker 3P 125A 1250Im 15kA VA57F35-340010 UHL3 400V AC KEAZ 109296
SKU: 109296