Systeme Electric
Residual current circuit breaker 2p (1P+N) B 13A 100mA type A 6kA Systeme9 230V SE S9D47613 Systeme Electric
SKU: S9D47613
ETIM: EC000905
7,097 ₽
Get back 70 ₽ in points
Analogues by specifications
Stock by warehouse
Residual Current Circuit Breaker (RCCB) S9D, Systeme9 series, Systeme Electric, 1P+N, rated current 13 A, characteristic B, Icn = 6 kA, leakage current = 100 mA, type A. Complies with GOST IEC 61009-1 and GOST IEC 60947-2 standards. Used in electrical networks with voltage 230 V. Designed to protect circuits from overcurrents and to protect people from leakage currents during direct (10 and 30mA) and indirect (100mA) contact with live parts, as well as to protect electrical installations from fire (300mA). Operating principle is electromechanical. Neutral on the left. Equipped with double safe terminals for separate conductor mounting, instantaneous switching mechanism, contact group status indicator, and separate indicators for tripping due to overcurrent or leakage current. Mounts on a DIN rail using two-position latches, with the possibility of disassembly without removing the PIN busbar.
Mounting installation depth
45 мм
Number of protected poles
1
Rated breaking capacity per IEC 60947-2
6 кА
Rated short-circuit breaking capacity Icn per EN 61009-1
6 кА
Rated impulse voltage
4 кВ
Rated voltage
230 В
Rated insulation voltage Ui
500 В
Rated current
13 А
Rated leakage current
Please provide the text you would like me to translate. мА
Total number of poles
2
Ambient operating temperature to
60 град.C
Ambient operating temperature from
-25 град.C
Current type
Alternating current (AC)
With switched neutral conductor
Yes
Flexible stranded conductor cross-section up to
16 кв.мм
Stranded flexible conductor cross-section from
16 кв.мм
Solid conductor cross-section to
25 кв.мм
Solid conductor cross-section from
25 кв.мм
Pollution degree (number)
3
IP protection rating
IP20
Residual current type
Please provide the text you would like me to translate.
Tripping characteristic
Without time delay
Tripping characteristic
Please provide the text you would like me to translate.
Frequency (Hz)
50/60 Hz
Width in modular units
2
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
6611 ₽
CHINT Residual current circuit breaker 2P C 32A 30mA type A 10kA NB1L (54mm) (R) CHINT 205014
SKU: 205014
6423 ₽
CHINT Residual current circuit breaker 4p C 40A 30mA type AC 6kA NB1L-40 (R) CHINT 198139
SKU: 198139
35550 ₽
CHINT Residual current circuit breaker 2P (1P+N) C 20A 10mA type A 6kA AVDT NB2LE-80ZT electronic (R) CHINT 448151
SKU: 448151
3985 ₽
CHINT Residual current circuit breaker 4p (3P+N) C 10A 100mA type AC 6kA AVDT NXBLE-63YH C10 electron. (R) CHINT 539740
SKU: 539740