Systeme Electric
Residual current circuit breaker 2p (1P+N) C 13A 100mA type A 6kA Systeme9 230V SE S9D57613 Systeme Electric
SKU: S9D57613
ETIM: EC000905
6,463 ₽
Get back 64 ₽ in points
Analogues by specifications
Stock by warehouse
Residual Current Circuit Breaker (RCCB) S9D, Systeme9 series, Systeme Electric, 1P+N, rated current 13 A, characteristic C, Icn = 6 kA, leakage current = 100 mA, type A. Complies with the requirements of standards GOST IEC 61009-1 and GOST IEC 60947-2. Used in electrical networks with a voltage of 230 V. Designed to protect circuits from overcurrents and to protect people from leakage currents during direct (10 and 30mA) and indirect (100mA) contact with live parts, as well as to protect electrical installations from fire (300mA). Operating principle - electromechanical. Neutral on the left. Equipped with double safe terminals for separate conductor installation, an instantaneous switching mechanism, a contact group status indicator, and separate trip indicators for overcurrent or leakage current. Mounts on a DIN rail using two-position clips, with the possibility of removal without removing the PIN busbar.
Mounting installation depth
45 мм
Number of protected poles
1
Rated breaking capacity per IEC 60947-2
6 кА
Rated short-circuit breaking capacity Icn per EN 61009-1
6 кА
Rated impulse voltage
4 кВ
Rated voltage
230 В
Rated insulation voltage Ui
500 В
Rated current
13 А
Rated leakage current
Please provide the text you would like me to translate. мА
Total number of poles
2
Ambient operating temperature to
60 град.C
Ambient operating temperature from
-25 град.C
Current type
Alternating current (AC)
With switched neutral conductor
Yes
Flexible stranded conductor cross-section up to
16 кв.мм
Stranded flexible conductor cross-section from
16 кв.мм
Solid conductor cross-section to
25 кв.мм
Solid conductor cross-section from
25 кв.мм
Pollution degree (number)
3
IP protection rating
IP20
Residual current type
Please provide the text you would like me to translate.
Tripping characteristic
Without time delay
Tripping characteristic
It seems your message was cut off. Please provide the text you would like me to translate from Russian to English, and I will follow your instructions strictly.
Frequency (Hz)
50/60 Hz
Width in modular units
2
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
56304 ₽
CHINT Residual current circuit breaker 4p (3P+N) C 6A 100mA type AC 6kA AVDT NB2LE-80ZT electronic (R) CHINT 448238
SKU: 448238
39182 ₽
CHINT Residual current circuit breaker 4p (3P+N) D 10A 100mA type A 6kA AVDT NB2LE-80ZT D10 electron. (R) CHINT 560168
SKU: 560168
5165 ₽
CHINT Residual current circuit breaker 4p C 10A 100mA type A 6kA AVDT NXBLE-63YH C10 electron. (R) CHINT 540108
SKU: 540108
5518 ₽
CHINT Residual current circuit breaker 4p D 63A 300mA type AC 6kA AVDT NXBLE-63YH D63 electron. (R) CHINT 539934
SKU: 539934