Legrand
Residual Current Device (RCD) 2p 25A 300mA type AC RX3 IEK Leg 402032 Legrand (IEK group)
SKU: 402032
ETIM: EC000003
145,609 ₽
Get back 1,456 ₽ in points
Order multiple: 24 шт
Analogues by specifications
Stock by warehouse
Residual current operated circuit breakers without overcurrent protection (RCCB) with direct indication of the main contact position are designed for load control and disconnection of electrical circuits, protection of persons against direct and indirect contact, and protection of electrical installations against insulation failure.
Additional equipment possible
No
Mounting installation depth
60.9 мм
Number of poles
2
Maximum supply cable cross-section
16 кв.мм
Mech. endurance
20000
Rated impulse withstand voltage
4
Rated tripping residual current
300
Rated leakage current
0.30
Rated breaking capacity
6 кА
Rated breaking capacity in accordance with EN 60898
6 кА
Rated breaking capacity per IEC 60947-2
6 кА
Rated ultimate breaking capacity (Icw)
10 кА
Rated impulse voltage
4 кВ
Rated voltage
250 В
Rated insulation voltage Ui
250 В
Rated voltage from
230 В
Rated operating voltage
230
Rated current
25 А
Rated leakage current
It appears your message contains only ".3". Please provide the text you would like me to translate from Russian to English, and I will follow your instructions strictly. мА
Ambient operating temperature to
70 град.C
Ambient operating temperature from
-25...70 град.C
Leakage current adjustment
No
Adjustable delay time
No
Operating mode
Continuous-S1
With short-time delayed tripping
No
With interlock device
No
Selective protection
No
Flexible stranded conductor cross-section up to
35 кв.мм
Stranded flexible conductor cross-section from
10 кв.мм
Solid conductor cross-section to
50 кв.мм
Solid conductor cross-section from
16 кв.мм
Mounting method
On DIN rail
Pollution degree (number)
2
IP protection rating
IP20
Installation size (in accordance with DIN 43880)
1
Residual current type
Alternating current (AC)
Conditional rated residual short-circuit current
0.25
Resistance to current surges
4 кА
Frequency
50/60 Hz Гц
Frequency (Hz)
50/60 Hz
Width in modular units
2
Electrical endurance
10000
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
1099 ₽
Generica (Группа IEK) Residual Current Circuit Breaker (RCCB) VD1-63 2P 63A 30mA GENERICA MDV15-2-063-030
SKU: MDV15-2-063-030
2512 ₽
Generica (Группа IEK) Residual Current Circuit Breaker (RCCB) VD1-63 4P 50A 100mA GENERICA MDV15-4-050-100