IEK
Residual Current Device (RCD) 4p 40A 100mA type AC RX3 IEK Leg 402067 Legrand (IEK group)
SKU: 402067
ETIM: EC000003
45,048 ₽
Get back 450 ₽ in points
Promo code
FIRST
— cashback ×3 on your first order: 3% in points on the first 50,000 ₽
Order multiple: 12 шт
Analogues by specifications
Stock by warehouse
Residual current operated circuit breakers without overcurrent protection (RCCB) with direct indication of the main contact position are designed for load control and disconnection of electrical circuits, protection of persons against direct and indirect contact, and protection of electrical installations against insulation failure.
Additional equipment possible
No
Mounting installation depth
60.9 мм
Number of poles
4
Maximum supply cable cross-section
16 кв.мм
Mech. endurance
20000
Rated impulse withstand voltage
4
Rated tripping residual current
100
Rated leakage current
0.10
Rated breaking capacity
6 кА
Rated breaking capacity in accordance with EN 60898
6 кА
Rated breaking capacity per IEC 60947-2
6 кА
Rated ultimate breaking capacity (Icw)
10 кА
Rated impulse voltage
4 кВ
Rated voltage
400 В
Rated insulation voltage Ui
400 В
Rated voltage from
400 В
Rated operating voltage
400
Rated current
40 А
Rated leakage current
.1 мА
Ambient operating temperature to
70 град.C
Ambient operating temperature from
-25...70 град.C
Leakage current adjustment
No
Adjustable delay time
No
Operating mode
Continuous-S1
With short-time delayed tripping
No
With interlock device
No
Selective protection
No
Flexible stranded conductor cross-section up to
35 кв.мм
Stranded flexible conductor cross-section from
10 кв.мм
Solid conductor cross-section to
50 кв.мм
Solid conductor cross-section from
16 кв.мм
Mounting method
On DIN rail
Pollution degree (number)
2
IP protection rating
IP20
Installation size (in accordance with DIN 43880)
1
Residual current type
Alternating current (AC)
Conditional rated residual short-circuit current
0.25
Resistance to current surges
4 кА
Frequency
50/60 Hz Гц
Frequency (Hz)
50/60 Hz
Width in modular units
4
Electrical endurance
10000
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
1790 ₽
КЭАЗ Residual Current Device (RCD) 4p 40A 30mA type A VD1-63 4240-A UHL4 KEAZ 221971
SKU: 221971
2980 ₽
КЭАЗ Residual Current Device (RCD) 2p 40A 300mA type AC 4.5kA OptiDin DM63-2440 УХЛ4 КЭАЗ 343901
SKU: 343901
2135 ₽
Эра Residual current device (RCD) 2p 80A 100mA type S VD1-63 PRO electromechanical VD2EM80S100 Era Б0061792
SKU: Б0061792
1946 ₽
EKF Residual current circuit breaker VD-100 2P 25A 10mA type AC electromechanical 4.5kA PROXIMA EKF elcb-2-25-10-em-pro
SKU: elcb-2-25-10-em-pro