IEK
ARMAT Residual current circuit breaker B10N 2P B32 100mA type A IEK AR-B10N-2-B032A100
SKU: AR-B10N-2-B032A100
ETIM: EC000905
706,380 ₽
Get back 7,063 ₽ in points
Promo code
FIRST
— cashback ×3 on your first order: 3% in points on the first 50,000 ₽
Order multiple: 60 шт
Analogues by specifications
ARMAT B10N series residual current circuit breakers (RCCB) are a reliable solution for industrial, energy, and domestic applications. B10N is functionally independent of mains voltage, ensuring functional operation even in the event of a neutral loss. A rated maximum breaking capacity of 10 kA guarantees reliable device operation even at high short-circuit currents. The B10N 2P pole topology means that overcurrent and short-circuit protection functions, as well as the arc-extinguishing ferromagnetic grid, are implemented in each pole. An independent free-trip mechanism with instantaneous switching ensures safe connection, and the protective shutter prevents incorrect connection and installation errors. PIN and FORK busbar connections are implemented at the top and bottom of the device. B10N allows the connection of any additional ARMAT AUX series modular devices. The product range includes devices with rated currents from 8 to 32 A, trip characteristics B and C, and protection types AC and A with rated residual currents of 30, 100, 300 mA.
Mounting installation depth
75.6 мм
Current limiting class
3
Number of protected poles
2
Number of poles
2
Maximum supply cable cross-section
16 кв.мм
Mechanical durability
20000
Tightening torque of contact terminal screws
5
Availability of residual current release
Yes
Thermal release available
Yes
Electromagnetic release present
Yes
Electronic release available
No
Rated impulse withstand voltage
4
Rated non-tripping residual current
0.5IΔn
Rated differential making and breaking capacity
10000
Rated breaking capacity in accordance with EN 60898
10 кА
Rated breaking capacity per IEC 60947-2
10 кА
Rated voltage
230 В
Rated current
32 А
Rated leakage current
0.1 мА
Total number of poles
2
Operating mode
Continuous
Current type
Alternating current (AC)
With switched neutral conductor
Yes
Tripping system
Thermal, electromagnetic
Mounting method
On DIN rail
Pollution degree (number)
2
IP protection rating
IP20
Operating temperature
-25...55
Residual current type
A
Connection type
Screw connection
Tripping characteristic
B
Frequency (Hz)
50 Hz
Width in modular units
2
Electrical wear resistance
10000
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
857 ₽
EKF RCBO AD-2 2P 32A characteristic C 30mA type AC electronic 4.5kA PROXIMA EKF DA2-32-30-pro
SKU: DA2-32-30-pro
1625 ₽
CHINT Residual current circuit breaker 2p (1P+N) C 20A 30mA type A 6kA AVDT NXBLE-63YH C20 electron. (R) CHINT 515280
SKU: 515280
1395 ₽
IEK KARAT Residual Current Circuit Breaker (RCCB) AVDT32 C25 300mA type AC 4.5kA selective IEK KA-VD10-1-025-C-300-AC-1S
SKU: KA-VD10-1-025-C-300-AC-1S
1492 ₽
IEK Residual Current Circuit Breaker (RCCB) VD1-63 2P 25A 30mA IEK MDV10-2-025-030
SKU: MDV10-2-025-030