Контактор (группа IEK)
Circuit breaker VA51-39-400A-344730-4000-660V-HP24DC-20UKHL3 Contactor 1009870
SKU: 1009870
ETIM: EC000228
50,712 ₽
Get back 507 ₽ in points
Promo code
FIRST
— cashback ×3 on your first order: 3% in points on the first 50,000 ₽
Analogues by specifications
Stock by warehouse
Switches are designed for conducting current in normal mode and disconnecting current during short circuits, overloads, and impermissible voltage drops, as well as for infrequent (up to 6 per day) operational switching on and off of electrical circuits and are designed for operation in electrical installations with a nominal voltage of up to 660 V AC at a frequency of 50 and 60 Hz and up to 440 V DC. Included in the Ministry of Industry and Trade register.
Main circuit connection type
Front connection
Built-in ground fault protection
No
Built-in motor drive
Yes
Height
250.0 мм
Height
250.0 мм
Depth
270.0 мм
Mounting installation depth
44 мм
Overload protection device setting range to
400 А
Setting range of overload protection device from
400…400 А
Instantaneous short-circuit release setting range to
4000 А
Instantaneous short-circuit release setting range from
4000…4000 А
For flush mounting
Yes
Design
Stationary
Number of auxiliary NO contacts
0
Number of auxiliary break contacts
0
Number of protected poles
3
Number of poles
3
Design
Device complete with housing
Motor drive optional
No
Rated service short-circuit breaking capacity Ics
35
Rated short-circuit breaking capacity Icu IEC 60898 at 230 V
10 кА
Rated short-circuit breaking capacity Icu IEC 60898 at 400 V
6 кА
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230V
10 кА
Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V
6 кА
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz
35 кА
Rated impulse voltage
4 кВ
Rated voltage
400 В
Rated insulation voltage Ui
500 В
Rated voltage up to
660 В
Rated voltage from
0...660 В
Rated current
400 А
Rated continuous current Iu
400 А
Total number of poles
3
Suitable for DIN-rail mounting
No
Power loss
150 Вт
Ambient operating temperature to
70 град.C
Ambient operating temperature from
-25 град.C
Current type
Alternating current (AC)
With minimum voltage protection
Yes
With switched neutral conductor
No
Flexible stranded conductor cross-section up to
25 кв.мм
Stranded flexible conductor cross-section from
1.5 кв.мм
Solid conductor cross-section to
35 кв.мм
Solid conductor cross-section from
1.5 кв.мм
Tripping system
Thermal-magnetic
Pollution degree (number)
2
IP protection rating
IP20
Product/component type
Moulded case circuit breaker
Main electrical circuit connection type
Screw connection
Control element type
Lever (toggle)
Tripping characteristic
C
Frequency
50 Гц
Frequency at
60 Гц
Frequency from
50 Гц
Width
250.0 мм
Width in modular units
3
0
★★★★★
0 reviews
No reviews yet. Be the first!
Leave a review
Related products
3411 ₽
Legrand (группа IEK) Circuit breaker 3p 175A 18kA DRX250 stationary Leg 027102 Legrand
SKU: 027102
5377 ₽
КЭАЗ Circuit breaker 1p 16A 3I 6kA ВА21-29-120010 У3 400V AC КЭАЗ 102177
SKU: 102177
3331 ₽
КЭАЗ Miniature circuit breaker 1p 16A 5Icn 1.8kA A63 M XL3 400V AC KEAZ 104078
SKU: 104078
4839 ₽
КЭАЗ Circuit breaker 3p 80A 10Iin 6kA AE2053M-100 U3 400V AC KEEZ 104432
SKU: 104432